INSTALLATION

7  UNPACKING THE PRODUCT

Heaters 

B

 

IDRA MS

 are supplied in a single package 

on a wooden pallet.

The following items are delivered in a plastic bag inside the 

packaging:

-  Instruction manual

-  Bar code label

-  Hydraulic test certificate

-  Energy label (to be applied to device upon installa-

tion)

The instruction manual is an integral part of the so-

lar storage cylinder. Once located, read it thoroughly 

and keep it safe.

For handling operations, thoroughly follow the in-

structions on device package label.

8  PLACE OF INSTALLATION

B

 

IDRA MS

 storage cylinders can be installed in any 

room where there is no specific requirement for an electri-

cal protection rating higher than IP X0D.

≥ 0,3 m

≥ 0,3 m

≥ 0,3 m

≥ 0,6 m

≥ 0,7 m

NOTE:

 the above-indicated dimensions are recommended 

for a correct maintenance and access to the device.

9  INSTALLATION IN OLDER 

SYSTEMS AND SYSTEMS 

REQUIRING MODERNISATION

When installing 

B

 

IDRA MS

 storage cylinders in old sys-

tems or systems requiring modernisation, always perform 

the following checks.

-  Make  sure  that  the  system  is  fitted  with  safety  and 

control devices in accordance with applicable legis-

lation and standards

-  Make sure that the central heating circuit has been 

flushed out to remove all sludge and lime scale, and 

has been vented and seal tested

-  Make sure that a suitable water treatment system is 

installed if the quality of the supply/recirculation water 

so demands. (Refer to the reference values listed in 

the table alongside.)

10  WATER QUALITY 

REQUIREMENTS

REFERENCE VALUES

pH

6-8

Electrical conductivity

less than 200 μS/cm (25°C)

Chlorine ions

less than 50 ppm

Sulphuric acid ions

less than 50 ppm

Total iron

less than 0.3 ppm

Alkalinity M

less than 50 ppm

Total hardness

less than 35°F

Sulphur ions

none

Ammonia ions

none

Silicon ions

less than 30 ppm

The values above ensure proper operation of the system. 

Refer to the limit values specified in the current standards 

and regulations on the installation site.

Installation

Содержание IDRA MS 150

Страница 1: ...Installation and Operation Manual Storage cylinder IDRA MS Installation and Operation Manual EN ...

Страница 2: ... improper installation adjustment maintenance or use b The product must be serviced at least once a year Servicing must be arranged in advance with the B Technical Assistance Centre b All servicing and repairs must be performed by a qualified heating engineer b If water leaks from the storage cylinder turn off the water supply and contact B s Technical Assis tance Centre or a qualified heating eng...

Страница 3: ...for easy cleaning and mainte nance of the anti corrosion magnesium anode 4 IDENTIFICATION The B IDRA MS solar heaters can be identified by Data plate This lists the technical specifications and performance of the product BALLON Modele Model Fabrication Année bar W l W kW l h BOLLITORE Modello Codice Matricola Anno m2 kW T067774IFE T067774IFE BOILER Year Serial number V Hz Potenza elettrica assorbi...

Страница 4: ...DHW 10 45 C at the different coil inlet temperatures and with the indicated delta T Coil delivery temperature 80 C T 20 C 27 kW 660 l h 70 C T 20 C 19 kW 480 l h 60 C T 10 C 11 kW 280 l h 50 C T 10 C 8 kW 190 l h Set up time required to heat the boiler to 60 C coil probe point reference with primary exchanger at the indi cated delivery temperature and with the indicated delta T Coil delivery tempe...

Страница 5: ...oil probe point reference and pri mary exchanger at the indicated delivery temperature considering an increase of the domestic water tempera ture of 30 C between inlet and outlet according to EN 12897 Coil delivery temperature 60 C 223 l Quantity of domestic water obtained in 10 with boiler pre heated to 45 C coil probe point reference and pri mary exchanger at the indicated delivery temperature c...

Страница 6: ...NISATION When installing B IDRA MS storage cylinders in old sys tems or systems requiring modernisation always perform the following checks Make sure that the system is fitted with safety and control devices in accordance with applicable legis lation and standards Make sure that the central heating circuit has been flushed out to remove all sludge and lime scale and has been vented and seal tested...

Страница 7: ... 33 300 mm DF Flange internal diameter 130 mm A 171 mm B 243 mm C 323 mm D 431 mm E 523 mm F 663 mm G 920 mm H 1088 mm I 604 mm L M8 threaded inserts for grounding point accessory handles connection 700 mm b We recommend that you install isolating valves in the outlet and return lines b Check the efficiency of the seals when filling refilling the storage cylinder b In case of a probe any electric ...

Страница 8: ...ricity supply ON at the mains power switch and at control panel switch if fitted 14 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C set the heater tem perature control where available to the minimum value b If the temperature to which the heater is exposed can fall below 0 C frost ...

Отзывы: