background image

This manual, Code 20129019 - Rev. 3 (01/18) comprises 8 pages.

2

GENERAL INFORMATION

RANGE

MODEL

CODE

IDRA MS 150

20128979

ACCESSORIES

For a complete list of accessories and details of their com-

patibility, refer to the Catalogue.

Dear heating engineer,

We would like to congratulate you on having recommend-

ed a 

B

 Storage cylinder unit: a modern product that's 

capable of ensuring a high degree of reliability, efficiency, 

quality and safety.

While your technical skills and knowledge will certainly be 

more than sufficient, this booklet contains all the informa-

tion that we have deemed necessary for the device's cor-

rect and easy installation.

Thank you again, and keep up the good work,

Beretta

CONFORMITY

B

 storage cylinders conform to DIN 4753-3 and UNI 

EN 12897 standards.

CONTENTS

The following symbols are used in this manual:

CAUTION! =

 Identifies actions that require caution 

and adequate preparation.

STOP! =

 Identifies actions that you MUST NOT do.

1  GENERAL SAFETY INFORMATION

Check that the product is complete, undamaged and 

as ordered as soon as you receive it. Report any dis-

crepancies or damage to the 

B

 dealer who sold 

it.

This product must be installed by a legally qualified 

heating engineer. On completion of the installation, 

the installer must issue the owner with a declaration 

of conformity confirming that the installation has been 

completed to the highest standards in compliance 

with the instructions provided by 

B

 in this instruc-

tion manual, and that it conforms to all applicable 

laws and standards.

This product must only be used for the purpose 

for which it is designed and made, as specified by 

B

B

 declines all responsibility, contractual or 

other, for damage to property or injury to persons or 

animals caused by improper installation, adjustment, 

maintenance or use.

The product must be serviced at least once a year. 

Servicing must be arranged in advance with the 

B

 Technical Assistance Centre.

All servicing and repairs must be performed by a 

qualified heating engineer.

If water leaks from the storage cylinder, turn off the 

water supply and contact 

B

’s Technical Assis-

tance Centre or a qualified heating engineer imme-

diately.

If the product is not going to be used for an extended 

period of time, contact the manufacturer’s Technical 

Assistance Centre to have at least the following oper-

ations performed:

- Close the shut-off cocks for the domestic hot water 

circuit

- Shut down the boiler connected to the storage cylin-

der as instructed in its own manual

- Switch the storage cylinder OFF at the control panel 

(if fitted) and at the mains power switch

- Drain the central heating circuit and domestic hot 

water circuit if there is any risk of freezing.

This instruction manual is an integral part of the prod-

uct. It must be kept safe and must ALWAYS accom-

pany the product, even if it is sold to another owner or 

transferred to another user or to another installation. 

If you lose this manual, order a replacement immedi-

ately. Keep the product purchase documents to be 

presented to the 

B

 authorised Technical Assis-

tance Centre to request a service call under warranty.

This manual, Code

- Rev.

comprises

pages.

ENGLISH

General information

GENERAL INFORMATION                                            2

General Safety Information  . . . . . . . . . . . . . . . . . 2

2 Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Description of the appliance  . . . . . . . . . . . . . . . . 3

Identification  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

System layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Technical specifications  . . . . . . . . . . . . . . . . . . . 4

INSTALLATION                                                              6

Unpacking the product  . . . . . . . . . . . . . . . . . . . . 6

Place of installation  . . . . . . . . . . . . . . . . . . . . . . . 6

Installation in older systems and systems 

requiring modernisation. . . . . . . . . . . . . . . . . . . . 6

10 

Water quality requirements  . . . . . . . . . . . . . . . . . 6

11 

Water connections . . . . . . . . . . . . . . . . . . . . . . . . 7

12 

Recycling and disposal . . . . . . . . . . . . . . . . . . . . 8

END USER                                                                    8

13 Start-up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

14 

Temporary shutdown . . . . . . . . . . . . . . . . . . . . . . 8

15 

Preparing for extended periods of disuse . . . . . . 8

16 

External maintenance  . . . . . . . . . . . . . . . . . . . . . 8

Содержание IDRA MS 150

Страница 1: ...Installation and Operation Manual Storage cylinder IDRA MS Installation and Operation Manual EN ...

Страница 2: ... improper installation adjustment maintenance or use b The product must be serviced at least once a year Servicing must be arranged in advance with the B Technical Assistance Centre b All servicing and repairs must be performed by a qualified heating engineer b If water leaks from the storage cylinder turn off the water supply and contact B s Technical Assis tance Centre or a qualified heating eng...

Страница 3: ...for easy cleaning and mainte nance of the anti corrosion magnesium anode 4 IDENTIFICATION The B IDRA MS solar heaters can be identified by Data plate This lists the technical specifications and performance of the product BALLON Modele Model Fabrication Année bar W l W kW l h BOLLITORE Modello Codice Matricola Anno m2 kW T067774IFE T067774IFE BOILER Year Serial number V Hz Potenza elettrica assorbi...

Страница 4: ...DHW 10 45 C at the different coil inlet temperatures and with the indicated delta T Coil delivery temperature 80 C T 20 C 27 kW 660 l h 70 C T 20 C 19 kW 480 l h 60 C T 10 C 11 kW 280 l h 50 C T 10 C 8 kW 190 l h Set up time required to heat the boiler to 60 C coil probe point reference with primary exchanger at the indi cated delivery temperature and with the indicated delta T Coil delivery tempe...

Страница 5: ...oil probe point reference and pri mary exchanger at the indicated delivery temperature considering an increase of the domestic water tempera ture of 30 C between inlet and outlet according to EN 12897 Coil delivery temperature 60 C 223 l Quantity of domestic water obtained in 10 with boiler pre heated to 45 C coil probe point reference and pri mary exchanger at the indicated delivery temperature c...

Страница 6: ...NISATION When installing B IDRA MS storage cylinders in old sys tems or systems requiring modernisation always perform the following checks Make sure that the system is fitted with safety and control devices in accordance with applicable legis lation and standards Make sure that the central heating circuit has been flushed out to remove all sludge and lime scale and has been vented and seal tested...

Страница 7: ... 33 300 mm DF Flange internal diameter 130 mm A 171 mm B 243 mm C 323 mm D 431 mm E 523 mm F 663 mm G 920 mm H 1088 mm I 604 mm L M8 threaded inserts for grounding point accessory handles connection 700 mm b We recommend that you install isolating valves in the outlet and return lines b Check the efficiency of the seals when filling refilling the storage cylinder b In case of a probe any electric ...

Страница 8: ...ricity supply ON at the mains power switch and at control panel switch if fitted 14 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C set the heater tem perature control where available to the minimum value b If the temperature to which the heater is exposed can fall below 0 C frost ...

Отзывы: