Assembly & initial set-up
6
F.
Secure the arm (item 1) on the chute head (item
B) using the carriage bolt 1/4'' n.c. x 1'' (item 2),
four 5/16'' flat washers (item 3) and a nylon
insert lock nut (item 4).
The flat washers are positioned between the
head of the chute and the arm.
DO NOT TIGHTEN COMPLETELY so that the
deflector moves freely.
Installation of the electric control box
STEP 1 : relay installation
The purpose of the relay is to make sure
tractor ignition inserted
Identify the electrical wire ‘’Accessory’’.
Put the High/Low tension tester’s clamp on the negative
post (-) on the battery or on a metallic surface without
any paint.
Turn the key to the
Accessory
position. Insert the tip of
the tester in the hole at the back of the switch to touch
the metal wire. Usually, it is the red wire but can vary
from one tractor to another.
If the light on the tester lights up, turn the ignition key to
the
OFF
position. If the light turns off, the wire for
Accessory
has been identified. If the light stays
ON
,
repeat the operation on another wire.
Required conditions to identify the appropriate wire
· Accessory position: Tester is lighted up
· Off position: Tester light is turned off
Connect the control wire
Join the accessory wire (item 1) to the red wire (item 2)
using the instant connector (item 3).
IMPORTANT:
To prevent damaging the wires and getting
a bad connection, squash the guillotine (item A) on the
wires with a pair of pliers before closing the cap (item B)
on the instant connector.
1
3
1
2
B
A
2