Device view with opened lower section
12
Operating
Operating
WARNING
Suffocation risk due to low oxygen
levels when operating the device.
Ø
Ensure there is an adequate supply
of fresh air into the dwelling.
Ø
Make sure that the device is
connected to a window contact
switch for safe operation.
Ø
Make sure that all country specific
statutory regulations are observed
(e.g. in Germany the requirements of
the federal state's fire regulations).
The device is controlled using the control panel in the
middle of the front panel. This device is fitted with an
ECO Switch control panel. The symbols of the
functions which can be run are lit dimly. Touch the
control panel with your finger lightly to run the desired
function. The symbols of the active functions are
brightly lit.
The ECO switch control panel needs a short time
to adjust itself to the ambient conditions after the
mains power is turned on. During this time, it
cannot be operated.
Ø
Wait around 10 seconds after you turn the
mains power on.
If, after touching the panel repeatedly, the
function is not carried out:
Ø
Clean the control panel.
Ø
Briefly disconnect the mains power.
Ø
To activate the desired function, touch the respective
area with your finger.
Field functions in normal operation:
Multi-function touch pad for:
- Device ON/OFF
- Manual run-on function ON/OFF
- Configuration mode ON/OFF
Touch pad: Recirculated air mode ON/OFF
State of the control indicator:
- Brightly lit = recirculated air mode turned on
- Dimly lit = extraction mode turned on
- Blinking = change the recirculated air filter / filling
Touch pad: Hob lighting ON/OFF
Optional:
Touch pad: Effect lighting ON/OFF
Touch pad for power level 1
Touch pad for power level 2
Touch pad for power level 3
Touch pad for power level 4
Functions of the key fields in configuration mode:
Configuration mode ON/OFF
Turn on effect lighting (optional function)
Turn on extraction fan / recirculation
Flashing display air filter/filling reset and timer
ON/OFF
Automatic run-on ON/OFF