Disassembling the device
Installation instructions
59
Disassembling the device
DANGER
Lethal electric shock caused by
improperly performed electrical work.
Ø
Only allow work on the power supply
to be carried out by a qualified
electrician adhering to the country-
specific regulations and standards
(e.g. in Germany DIN 57100 / VDE
0100, part 701).
WARNING
Risk of falling when changing the filter
or during work carried out at height.
Ø
Use a stable step-ladder.
CAUTION
Risk of injury from falling parts.
Ø
Ensure that no-one is underneath
the device while working.
ATTENTION
Damage caused by falling parts.
Ø
Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
To remove the device you need a second person.
For this work step, you need a small flat-head
screwdriver, a Phillips screwdriver and a 2.5 mm ball
Allen key.
To remove the device, proceed as follows:
Ø
Disconnect the power supply to the device on all
poles.
Ø
Remove the mains plug.
Ø
Remove the connection cables for the wall box and
the multi-function contact, if fitted.
Only BLB 60 FLE and BLB 90 FLE:
Ø
Remove the connection cable for the fan.
Only for hybrid and extracted air mode:
Ø
Remove the exhaust pipe.
Only for hybrid and recirculated air mode:
Ø
Remove the filter.
Ø
Open the lower section.
Ø
Remove both screws on the levers.
ATTENTION
Damage caused by falling parts.
Ø
Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
Ø
Support the device with two people.
Ø
Push both levers backwards until they lock.
Ø
Lower the device with two people.
Ø
Loosen the screws on the brackets.
Ø
Remove the screws on the brackets.
Ø
Remove the brackets.
The device is disassembled.