Installing the device
50
Installation instructions
Only BLB 60 FLE / BLB 90 FLE:
Connect the connection cable of the fan
DANGER
Lethal electric shock caused by
improper connection.
Ø
Only allow work on the power supply
to be carried out by qualified, trained
electricians adhering to the country-
specific regulations and standards
(e.g. in Germany DIN 57100 / VDE
0100, part 701).
WARNING
Risk of falling during work carried out
at height.
Ø
Use a stable step-ladder.
CAUTION
Risk of injury from falling parts.
Ø
Ensure that no-one is underneath
the working area while you are
working.
ATTENTION
Damage caused by falling parts.
Ø
Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using a thick piece of cardboard.
The connection cable must be laid from the external
fan to the receptacle on the device.
Only BLB 60 FLE / BLB 90 FLE:
Receptacle pin assignments
The receptacle is wired as follows:
Receptacle
pin no.
Description
1
Level 1
2
Level 2
3
Level 3
4
Level 4
5
N
6
PE
Only BLB 60 FLE / BLB 90 FLE:
Controlling the individual fan speeds
Ø
Ensure that only one power level can be switched
on at any one time.
Level 1
PE
Level 2
N
Level 3
L
Level 4
For this work step, you do not need any tools to
connect the berbel connection cable.
Proceed as follows:
Ø
Push the plug of the connection cable firmly into the
receptacle on the device.
The connection cable for the fan is connected.