BENSON OIL UNIT HEATER
3
1.0 Compliance notices
The following information is relevant to the
Benson Oil Fired Unit Heater range (OUHA)
and (OUHC) manufactured by Benson
These heaters are manufactured within a
strictly controlled quality environment within
the parameters of
ISO 9001:2000.
The Benson OUHA (C) Heater range has
been tested and assessed for compliance
with the following European Directives.
Machinery Directive (89/392/EEC)
Low Voltage Directive (73/23/EEC & 93/68/
EEC)
Electromagnetic Compatibility Directive
(89/336/EEC & 91/31/EEC)
Product Liability Directive (65/374/EEC)
The manufacturer has taken reasonable and
practical steps to ensure that Benson Unit
Heaters are safe and without risk when
properly used. These heaters should
therefore only be used in the manner and
purpose for which they were intended, and in
accordance with the recommendations
detailed herewith.
The heaters have been designed,
manufactured, assembled, inspected, and
tested, with safety and quality in mind, there
are certain basic precautions which the
installer and user should be aware of, and
they are strongly advised to read the
appropriate sections of the information pack
accompanying the heater, prior to installation
or use.
Benson Heating supports all new products
being supplied to their customers with a
comprehensive information pack; this clearly
defines mandatory instructions for the safe
installation, use, and maintenance, of the
appliance (s).
Where proprietary items are incorporated
into Benson Heating products, detailed
information and instructions are also
provided as part of the information pack.
It is the responsibility of the installer, owner,
user, or hirer, of such products supplied by
Benson Heating, to ensure that they are
familiar with the appropriate information
manuals, supplied by the manufacturer, and
that they are suitably aware of the purpose of
the manuals and the safety instructions. In
addition, operators must be suitably trained
in the use of the appliance so as to ensure its
continued safe and efficient use.
Benson Heating has a commitment to
continuous improvement, and therefore
reserves the right to amend or change the
specification of the Unit Heater range subject
to compliance with the appropriate
European, National, and Local Regulations.
Contained within the text of the manual, the
words '
Caution'
and '
Warning'
are used to
highlight certain points.
Caution
is used when failure to follow or
implement the instruction (s) can lead to
premature failure or damage to the heater or
its component parts.
Warning
is used when failure to heed or
implement the instruction (s) can lead to not
only component damage, but also to a
hazardous situation being created where
there is a risk of personal injury.
The Benson OUHA ( C ) Range conform to
the following harmonized standards;
BS EN ISO 12100-1: 2003 &
BS EN ISO 12100-2: 2003
Safety of Machinery - Basic Concepts,
General Principles for Design
Technical principles and specifications
Part 1 & Part 2
BS EN 60204 - Part 1 : 1993
Safety of Machinery - Electrical Equipment
for Machines
Specification for General Requirements
BS EN 60335 - Part 1 : 1988
Safety of Household and Similar Electrical
Appliances General Requirements
BS EN 55014 - 1993
Limits and methods of
measurement of radio disturbance
characteristics of electrical motor-operated
and thermal appliances for household and
Содержание OUHA 100
Страница 19: ...BENSON OIL UNIT HEATER 19 9 0 Wiring Diagram OUHA 100 OUHA 140 ON OFF 33 65 100...
Страница 20: ...BENSON OIL UNIT HEATER 20 Wiring Diagram OUHA 200 OUHA 350 ON OFF 33 65 106...
Страница 21: ...BENSON OIL UNIT HEATER 21 Wiring Diagram OUHA 100 OUHA 140 HIGH LOW 33 65 107...
Страница 22: ...BENSON OIL UNIT HEATER 22 Wiring Diagram OUHA 200 OUHA 350 HIGH LOW 33 65 108...
Страница 23: ...BENSON OIL UNIT HEATER 23 Wiring Diagram OUHC 200 OUHC 350 ON OFF 33 65 191...
Страница 28: ...BENSON OIL UNIT HEATER 28 12 0 Heater Dimensions Axial Fan...