THEORY OF OPERATION
See Figure 10 for numbers in parenthesis.
The product is drawn from the underground storage tank through the strainer screen of
Filter (1
).
The
Rotary Vane Pumping Unit (2)
pressurizes the fluid.
Product enters the centrifugal
Air Separator Assembly (3)
. Any air present is forced out the air tube along with a small amount of liquid
into the
Atmospheric Chamber (4)
.
Product collected in the atmospheric chamber is returned to the pump intake across the non-return float when the liquid level in the
chamber lifts the float and valve assembly from its
Seat (5
). Any air is then vented to the atmosphere through the vent tube.
Air free product leaving the air separator opens the
Control Valve (6)
and is pumped to the meter. The control valve includes a built-in
Relief Valve (7)
which relieves excess pressure caused by hot weather expansion.
Product passes through the meter where it is accurately measured, then through the hose and nozzle into the vehicle being fueled.
Whenever the nozzle is not fully opened, some liquid is relieved into the pump intake through the
Bypass Valve (8)
.
FIGURE 10
Содержание T-75
Страница 4: ...Bennett T75 Operation Service Parts Manual Table of Contents 2 Page Intentionally Left Blank ...
Страница 13: ...Bennett T75 Operation Service Parts Manual Product Introduction 11 TUBULAR OUTLET MOTOR MOUNT OPTION FIGURE 7 ...
Страница 14: ...Bennett T75 Operation Service Parts Manual Product Introduction 12 SIDE INLET OPTION FIGURE 8 INLET CENTER ...
Страница 16: ...Bennett T75 Operation Service Parts Manual Operation 14 FIGURE 9 ...
Страница 18: ...Bennett T75 Operation Service Parts Manual Operation 16 FIGURE 11 ...
Страница 25: ...Bennett T75 Operation Service Parts Manual 23 Page Intentionally Left Blank ...