Bennett T75 Operation, Service, & Parts Manual
Operation
13
SECTION 3: OPERATION
OPERATION
The following section describes each of the main components of the T75 pumping unit and the interface characteristics at each component. Refer
to the diagram on the next page for item locations. For any questions, please contact Bennett Technical Support at 1-800-423-6638.
The pump assembly has the following main components:
(See Figure 9 for numbers in parenthesis.)
Body (1)
The inlet is designed to accept a triangular inlet flange with a 3-hole bolt pattern.
Cover (2)
The
Flanged Outlet
is used for direct meter mounting
The
Tubular Outlet
is used for remote meter mounting (as shown on page 6)
Filter (3)
located
in the horizontal position.
Note:
The filter cover includes a pipe plug to drain the pump.
An optional
Inlet Check Valve
(19)
is available to hold product in the suction line when the pump is turned off. It maintains a vacuum
in the line preventing fuel from leaking through a loose joint into the ground.
Rotating Pump (4)
with Radial Carbon Blades
The
Throwout Rings (5)
maintain contact of the blades to the stator.
The
Stator
(6)
turns clockwise and is tightly fitted in the pump body.
The
Rotor
(7)
is made of cast iron with a chrome-plated shaft.
The
Self-Lubricated Bearings
(21)
are used to prevent seizure when tank is pumped dry.
The
Cover
(8),
also of cast iron, encapsulates the rotor and the stator.
An
Air Elimination Assembly (9)
,
a patented fully static device, uses a vortex effect.
The insert
(10)
starts spinning the fluid.
The foam and the air pass through the
Tube
(11)
and evacuated through the
Orifice (12)
.
A
Drain Line Eliminator (13)
or atmospheric chamber of 1.2-gallon (4.5 liter) capacity.
The
Float Valve Assembly
(14)
provides for the recovery of liquid from the chamber, while air is evacuated through the
Vent Tube
(15).
A
Non-Return Float
(20)
seals the atmospheric chamber when the pump is turned off to prevent flooding and spilling out onto the
driveway.
A
Bypass Valve (16)
is used to limit the maximum working pressure.
Its cover includes a device to adjust the bypass pressure (optional in USA)
A
Control Valve Assembly (17)
assures that all downstream hydraulic components are filled with liquid. This valve has a
Relief Valve (18)
to relieve excess pressure.
NOTE: A diaphragm operated preset valve is available as an option.
Содержание T-75
Страница 4: ...Bennett T75 Operation Service Parts Manual Table of Contents 2 Page Intentionally Left Blank ...
Страница 13: ...Bennett T75 Operation Service Parts Manual Product Introduction 11 TUBULAR OUTLET MOTOR MOUNT OPTION FIGURE 7 ...
Страница 14: ...Bennett T75 Operation Service Parts Manual Product Introduction 12 SIDE INLET OPTION FIGURE 8 INLET CENTER ...
Страница 16: ...Bennett T75 Operation Service Parts Manual Operation 14 FIGURE 9 ...
Страница 18: ...Bennett T75 Operation Service Parts Manual Operation 16 FIGURE 11 ...
Страница 25: ...Bennett T75 Operation Service Parts Manual 23 Page Intentionally Left Blank ...