Triple Beast Installation Guide

 

 

 

 

Nicolas Benezan, Stauffenbergstr. 26, 72108 Rottenburg 
Phone: +49 (0) 7457/946365 0 benezan-electronics.de 

Page 

TripleBeast-NET Installation.docx22.09.2020 

 

Commissioning and troubleshooting 

If you are using the control unit for the first time, please check the following points again before switching it on: 

 

Are all terminal blocks correctly aligned in the slots? 

 

Is the power supply (24 to 55V=) correctly connected (terminal X1 on top 

and

 terminal V on the right)? 

 

If the supply voltage is higher than 30V, jumper JP3 must be set to position 13-14 (▪ ▪ ▬ ▪, limit switch supply 12V). 

 

Is the emergency stop switch connected? For test purposes only, a jumper may be connected between pins 5 and 6 of X2 
as an alternative. An emergency stop switch is legally required on a machine. 

If  these  requirements  are  met,  you  can  establish  the  connection  to  the  PC,  switch  on  the  supply  voltage  and  start  the  control 
software. After activating the software and successful connection in the Configuration->Hardware dialog, the status of the LED 
lights should be as follows: 

 

the two green LEDs "Power" and "Ready" must be lit, 

 

at the network socket the  LED "Network Carrier" (green) must light up, and the  LED "Network traffic" (yellow)  must 
blink evenly and fast 

 

the two red LEDs "Drive Fault" and "E-Stop" must be off 

 

the two yellow LEDs relay 1 and relay 2 must be off. 

If  this  is  not  the  case,  please  refer  to  the  chapter  "Troubleshooting"  below.  If  everything  is  in  order,  you  can  now  check  the 
movement of the motors and the function of the relays and switches. 
 

 

Содержание TripleBeast

Страница 1: ...still required The effort for mounting wiring and the possibilities for errors are thus reduced to a minimum The Triple BEAST offers all the advantages of the individual BEAST power amplifier at extre...

Страница 2: ...lutely necessary More detailed selection criteria are listed in the chapter0 3 A PC with Beamicon2 CNC software and a RJ45 network cable patch cable Please note that this version of the Triple BEAST i...

Страница 3: ...Signal input 7 Reference switch 4th axis voltage output 12 24V 8 Reference switch 4th axis Signal input Relay outputs 6 pin terminal X4 bottom left No Description 1 230V L Input 2 230V N Input 3 Relay...

Страница 4: ...d power supply consisting of transformer rectifier and filter capacitor is also suitable Please note however that the voltage range must be maintained even with mains and load fluctuations usually 10...

Страница 5: ...for all axes simultaneously Simultaneous operation of very small and very large motors is therefore not possible Depending on the selected range the fine adjustment can then be carried out separately...

Страница 6: ...jumpers These are numbered from right to left with no 12 to 16 and are described further below The LEDs on the upper side indicate the status of the PC interface LEDs Lettering Description 1 green Pow...

Страница 7: ...a red plug or X The network interface is galvanically isolated from the PC Power over Ethernet PoE is not supported Reference switch inputs Up to 4 switches or inductive sensors can be connected If th...

Страница 8: ...upply ground However this is not a problem with all modern frequency inverters because they have an isolated speed input Care should be taken with old thyristor controllers whose speed input is partia...

Страница 9: ...nected to the supply voltage of the power supply X1 5 This is useful if a 24V power supply unit is connected there and the switches used are inductive proximity switches or similar industrial sensors...

Страница 10: ...neously as a reference and limit switch The following output signals are available and can be assigned to the logical signals in the software right table Pin Name Signal Description Release Current re...

Страница 11: ...purposes only a jumper may be connected between pins 5 and 6 of X2 as an alternative An emergency stop switch is legally required on a machine If these requirements are met you can establish the conne...

Страница 12: ...selected if several modules are in the network 4 LED Charge Pump green is not lit a ChargePump signal not assigned or module is not connected b Software not started or running in demo mode 5 LED Drive...

Страница 13: ...age at the relay terminals 30 Vdc 250 Vac Current per relay contact X4 8 Aeff Current at brake relay X2 5 A Current at analog output 0 10V 20 mA Electrical connection values Parameters min max Unit Op...

Отзывы: