background image

Benezan Electronics

 

Hard- and software development

 

Triple Beast Installation Guide

 

 

 

 

Nicolas Benezan, Stauffenbergstr. 26, 72108 Rottenburg 
Phone: +49 (0) 7457/946365 0 benezan-electronics.de 

Page 

TripleBeast-NET Installation.docx22.09.2020 

 

 

Triple BEAST 

Bene’s Advanced Stepper Drive 

 

3-axis high performance power amplifier 

for stepper motors with integrated 

Interface card for 

Ethernet 

 

Installation manual 

 
 

Brief product description 

The  "Triple  BEAST"  is  a  complete  stepper  motor  controller  for  three  axes.  All  components  for  the  control  of  a  small  milling, 
engraving or turning machine are integrated in a housing with dimensions of only 100x102x55mm. Only a power supply unit for 
the power supply is still required. The effort for mounting, wiring and the possibilities for errors are thus reduced to a minimum. 

The Triple BEAST offers all the advantages of the individual BEAST power amplifier at extremely low cost, such as very quiet 

motor  running  with  continuous  sinusoidal  commutation  and  complete  short-circuit  and  overload  protection.  Only  the  maximum 
current  and  the  maximum  operating  voltage  are  limited  to  5A  and  55V  compared  to  the  "big  brother".  For  applications  with  4 
axes, or if a more powerful motor is required, a connection option for an additional output stage is available. 

The  network  version  of  the  Triple  BEAST  is  designed  for  operation  with  the  Beamicon2  CNC  control  software.  A  normal 

network  connection  with  RJ45  cable  is  used  for  data  transfer  from  the  PC.  No  LPT  port  is  required,  and  the  well-known 
limitations of step frequency and timing problems are a thing of the past.  

Содержание TripleBeast

Страница 1: ...still required The effort for mounting wiring and the possibilities for errors are thus reduced to a minimum The Triple BEAST offers all the advantages of the individual BEAST power amplifier at extre...

Страница 2: ...lutely necessary More detailed selection criteria are listed in the chapter0 3 A PC with Beamicon2 CNC software and a RJ45 network cable patch cable Please note that this version of the Triple BEAST i...

Страница 3: ...Signal input 7 Reference switch 4th axis voltage output 12 24V 8 Reference switch 4th axis Signal input Relay outputs 6 pin terminal X4 bottom left No Description 1 230V L Input 2 230V N Input 3 Relay...

Страница 4: ...d power supply consisting of transformer rectifier and filter capacitor is also suitable Please note however that the voltage range must be maintained even with mains and load fluctuations usually 10...

Страница 5: ...for all axes simultaneously Simultaneous operation of very small and very large motors is therefore not possible Depending on the selected range the fine adjustment can then be carried out separately...

Страница 6: ...jumpers These are numbered from right to left with no 12 to 16 and are described further below The LEDs on the upper side indicate the status of the PC interface LEDs Lettering Description 1 green Pow...

Страница 7: ...a red plug or X The network interface is galvanically isolated from the PC Power over Ethernet PoE is not supported Reference switch inputs Up to 4 switches or inductive sensors can be connected If th...

Страница 8: ...upply ground However this is not a problem with all modern frequency inverters because they have an isolated speed input Care should be taken with old thyristor controllers whose speed input is partia...

Страница 9: ...nected to the supply voltage of the power supply X1 5 This is useful if a 24V power supply unit is connected there and the switches used are inductive proximity switches or similar industrial sensors...

Страница 10: ...neously as a reference and limit switch The following output signals are available and can be assigned to the logical signals in the software right table Pin Name Signal Description Release Current re...

Страница 11: ...purposes only a jumper may be connected between pins 5 and 6 of X2 as an alternative An emergency stop switch is legally required on a machine If these requirements are met you can establish the conne...

Страница 12: ...selected if several modules are in the network 4 LED Charge Pump green is not lit a ChargePump signal not assigned or module is not connected b Software not started or running in demo mode 5 LED Drive...

Страница 13: ...age at the relay terminals 30 Vdc 250 Vac Current per relay contact X4 8 Aeff Current at brake relay X2 5 A Current at analog output 0 10V 20 mA Electrical connection values Parameters min max Unit Op...

Отзывы: