Instruction
Check and make sure that the connector
of the warning lamp is inserted well and that
the bulb works.
Disconnect the ECM and proceed to
location test 1.
Disconnect the warning lamp, proceed to
test 4.
Possible cause
MIL system damaged
Open or short circuit to the
chassis
Short circuit at the positive
battery pole (+)
Fault code
P1600
P1601
P1602
BAD FUNCTIONING OF THE ENGINE DIAGNOSIS WARNING LAMP (MIL) –
MC 1000 ECM
Instruction
Disconnect the warning lamp and proceed
to test 2
Restore the fault, proceed to test 5
Proceed to test 3
Locate and rectify the cable fault, proceed
to test 5
Procedere al test 4
Locate and rectify the cable fault, proceed
to test 5
Proceed to test 5
Locate and rectify the cable fault, proceed
to test 5
Activity carried out – terminate the test
Contact the Benelli assistance
Result
Ok
Fault
Ok
Short circuit
Ok
Open circuit
Ok
Short circuit
Ok
Fault persists
Test
1 - Check the integrity of the terminal
and the cable:
- ECM pin 1/D4
2 - Check the cable for short circuiting:
- ECM pin 1/D4 to the frame
3 - Check the continuity of the cable:
- instrument pin 15 to ECM pin 1/D4
4 - Check for short circuiting:
- ECM pin 1/D4 to ECM pin 2/E1
- Instrument pin 5 to instrument pin
15
5 - Reconnect the cabling, cancel the
fault code and activate the engine
to check the elimination of the fault
LOCATION TEST
Содержание Tornado Tre Novicento 903
Страница 1: ...UK 1 MF9_UK T T T T L I M I T E D E D I T I O N COPERTINA ...
Страница 2: ...UK 2 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 35: ...UK 35 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 36: ...UK 36 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 37: ...UK 37 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 38: ...UK 38 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 39: ...UK 39 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 40: ...UK 40 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 41: ...UK 41 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 42: ...UK 42 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 43: ...UK 43 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 44: ...UK 44 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 45: ...UK 45 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 46: ...UK 46 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 47: ...UK 47 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 48: ...UK 48 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 176: ...UK 176 MF9_UK T T T T L I M I T E D E D I T I O N Remove the five screws 6 Remove screw 7 Remove the two screws 8 ...
Страница 177: ...UK 177 MF9_UK T T T T L I M I T E D E D I T I O N Remove screw 9 Remove the two screws 10 Loosen and remove screw 11 ...
Страница 224: ...UK 224 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 301: ...UK 301 MF9_UK T T T T L I M I T E D E D I T I O N E E E E Electrical P P P P Plant 9 ELECTRICAL PLANT ...
Страница 318: ...UK 318 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 328: ...UK 328 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 333: ...UK 333 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 334: ...UK 334 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 335: ...UK 335 MF9_UK T T T T L I M I T E D E D I T I O N ...
Страница 336: ...UK 336 MF9_UK T T T T L I M I T E D E D I T I O N ...