4
1. Boiler use and advantages
Boiler use:
The BENEKOV S16 hot water boiler is designed for heating small, low-energy family houses, cottages and
other building facilities whose heat output demand does not exceed 20 kW.
The BENEKOV S26 hot water boiler is designed for heating family houses, cottages, office buildings, small
establishments and building facilities whose heat output demand does not exceed 26 kW.
The BENEKOV S51 hot water boiler is designed for heating medium-sized buildings - shops, schools,
recreational facilities, large family houses, office buildings, establishments and other building facilities, whose
heat output demand does not exceed 49 kW.
Boiler advantages:
•
Automatic boiler operation
•
Possibility of combustion of a renewable energy source in the form of wood pellets
•
Mechanical fuel supply from standardized container (or general bunker) into the combustion chamber
•
Possibility of increasing the capacity of the basic standardized fuel container with additional modules
•
Automatic cleaning of heat transfer surfaces of the heat exchanger
•
Simple, quick operation and maintenance
•
Low operating costs
•
3-draught design of the exchanger guaranteeing high efficiency
•
Low emissions for the neighbourhood
•
Controlled combustion assisted by lambda probe
•
Modulation of thermal output over the entire power output range
•
Possibility of connecting boiler auto ignition (optional)
•
Possibility to connect ash removing device (optional)
•
Modern design
2. Technical specifications
Tab. no. 1 Dimensions and technical parameters of boilers
Boiler type
BENEKOV
S16
BENEKOV
S26
BENEKOV
S51
Weight (boiler body + feeder
to the turnstile)
Kg
340
410
765
Water compartment volume
dm
3
62
89
175
Flue gas duct diameter
Mm
145
195
Boiler heat transfer surface
m
2
1,90
2,84
5,64
Boiler dimensions:
Mm
Fig. no. 5, 6, 7
Fig. no. 8, 9,
10
Boiler class according to
Č
SN
EN 303-5
5
Maximum permissible
operating pressure
Bar
2,0
Testing pressure
Bar
4,0
Recommended operating
temperature of heating water
°C
65 - 80
Lowest temperature of the
inlet water
°C
60
Содержание S16
Страница 1: ...BOILER OPERATING AND INSTALLATION INSTRUCTION MANUAL BENEKOV S16 BENEKOV S26 BENEKOV S51 ...
Страница 20: ...20 Fig no 14 Boiler ash remover for S51 Fig no 15 Boiler flue gas exhaust for S16 and S26 ...
Страница 27: ...27 Fig no 22 Connection dimensions of BENEKOV S26 boiler ...
Страница 28: ...28 Fig no 23 Connection dimensions of BENEKOV S51 boiler ...