26
- Flue gas exhaust connector
- Circulation pump connector
- Room thermostat connector, respectively the equitherm control
- Spontaneous combustion sensor connector
- Lambda probe connector
- Limit switch connector
Spare connector plugs (e.g. for connecting a room thermostat, circulation pump, etc.) are placed in a
package in the ash tray drawer during transport from the factory. Prior to putting the boiler in operation it is
necessary to fit all these loose connector plugs to the boiler, even if they are not used.
When connecting the connectors you must avoid any confusion. Please connect the connector plugs and
sockets with the identical symbols.
Before connecting the room thermostat, respectively equitherm control, it is necessary to remove bridging
from the plug of the relevant connector. The room thermostat connector, respectively equitherm control can
only be connected to a thermostat with free potentialless contact (eg. SIEMENS REV, HONEYWELL CM…).
No external voltage can be connected to any of these terminals.
Fig. no. 21 Connection dimensions of BENEKOV S16 boiler