XPR-10 Series Two-Post Lifts
57
P/N 5900951 — Rev. D — May 2019
Contact the Electrician
As mentioned previously, there are installation tasks that require a certified Electrician.
⚠
DANGER
All wiring
must
be performed by a licensed, certified Electrician.
The Electrician needs to:
•
Connect to power
. The Power Unit comes with a pigtail for wiring to a power source. Have your
Electrician connect a power cord with plug to the electrical box on the Lift (for connection to a
power outlet) or have them wire it directly into the electrical system at the Lift location.
•
Connect the Microswitch to the Power Unit
. The Microswitch (which is next to the Safety
Shutoff Bar) has to be wired to the Power Unit. The necessary wiring is included.
•
Install a Power Disconnect Switch
. Ensures you can quickly and completely interrupt
electrical power to the Lift in the event of an electrical circuit fault, emergency situation, or when
equipment is undergoing service or maintenance. You must put it within sight and easy reach of
the Lift operator. Refer to
Installing a Power Disconnect Switch
for more information.
•
Install a Thermal Disconnect Switch
. Ensures the equipment shuts down in the event of an
overload or an overheated motor. Refer to
Installing a Thermal Disconnect Switch
for
more information.
These installation tasks are described in detail in the following sections.
The Electrician is responsible for providing:
•
A power cord and appropriate 220 VAC plug for connecting to an appropriate power source or the
items required to connect to the facility’s power system
•
a Power Disconnect Switch
•
a Thermal Disconnect Switch
Additional information is supplied in the sections describing these tasks.
Wiring the Microswitch
This section describes how to wire the Microswitch;
installing
the Microswitch was described in
Installing the Overhead Assembly, Safety Shutoff Bar, and the Microswitch
.
The Lift comes with either one or two Microswitches, depending on the Power Unit:
•
One phase Power Units
. You need only one Microswitch, which must be wired between
incoming power and the Electrical Box on the Power Unit on one of the two “hot” wires.
•
Three phase Power Units
. You need two Microswitches, which must be wired between
incoming power and the Electrical Box on the Power Unit on two of the three hot wires. Both
Microswitches you receive are identical.
Important
: If wiring
two
Microswitches, they
must
be wired on two
different
hot wires.
Refer to the diagrams in
Wiring Diagrams
for detailed Microswitch wiring information.
The following procedure assumes the Microswitch is already in place. If it is not, refer to
Installing
the Overhead Assembly, Safety Shutoff Bar, and the Microswitch
to install it.
Содержание XPR-10 Series
Страница 9: ...XPR 10 Series Two Post Lifts 9 P N 5900951 Rev D May 2019 Specifications ...
Страница 77: ...XPR 10 Series Two Post Lifts 77 P N 5900951 Rev D May 2019 Labels ...
Страница 78: ...XPR 10 Series Two Post Lifts 78 P N 5900951 Rev D May 2019 ...
Страница 79: ...XPR 10 Series Two Post Lifts 79 P N 5900951 Rev D May 2019 ...
Страница 81: ...XPR 10 Series Two Post Lifts 81 P N 5900951 Rev D May 2019 ...
Страница 82: ...XPR 10 Series Two Post Lifts 82 P N 5900951 Rev D May 2019 ...
Страница 83: ...XPR 10 Series Two Post Lifts 83 P N 5900951 Rev D May 2019 ...
Страница 84: ...XPR 10 Series Two Post Lifts 84 P N 5900951 Rev D May 2019 ...
Страница 85: ...XPR 10 Series Two Post Lifts 85 P N 5900951 Rev D May 2019 ...
Страница 86: ...XPR 10 Series Two Post Lifts 86 P N 5900951 Rev D May 2019 ...
Страница 87: ...XPR 10 Series Two Post Lifts 87 P N 5900951 Rev D May 2019 ...
Страница 88: ...XPR 10 Series Two Post Lifts 88 P N 5900951 Rev D May 2019 ...
Страница 91: ...XPR 10 Series Two Post Lifts 91 P N 5900951 Rev D May 2019 Maintenance Log ...
Страница 92: ...1645 Lemonwood Drive Santa Paula CA 93060 USA 2019 by BendPak Inc All rights reserved bendpak com ...