The following information can be utilized to recognize and correct probable malfunctions.
Table 6-1: KI 300 Troubleshooting
Symptom
Possible Solutions
Attitude remains Red-
X’ed
Ensure proper supply power is available.
Return unit for service.
Airspeed remains Red-
X’ed
Ensure proper supply power is available.
Ensure airspeed limit has not been exceeded.
Return unit for service.
Altitude remains Red-
X’ed
Ensure proper supply power is available.
Ensure altitude limit has not been exceeded.
Return unit for service.
Battery icon is Red-
X’ed
Ensure battery is correctly installed.
Perform battery load test.
Replace battery.
Return unit for service.
Battery icon is Red-
X’ed
For deeply discharged batteries, pre-charge as follows:
1.
Apply power for 10 minutes
2.
Momentarily remove power
3.
Re-apply power.
4.
Verify charging cycle starts correctly.
On Ground, Cross-Check
remains annunciated
Ensure proper supply power is available.
During power-on, ensure minimal aircraft motion is present.
Return unit for service.
Aligning message remains
annunciated
Ensure proper supply power is available.
During power-on, ensure minimal aircraft motion is present.
Return unit for service.
Altitude shows error
Perform altitude trim procedure.
Return unit for service.
Airspeed shows error
Perform airspeed trim procedure.
Return unit for service.
Attitude shows error
Set panel tilt correctly.
Set roll trim correctly.
Return unit for service.
IVSI shows constant offset
Set panel tilt correctly.
Set roll trim correctly.
Return unit for service.
Memory Error is shown
Return unit for service.