____________________________________________________________________________
89000004-101
KI 300 Installation Manual
Rev 1
5-2
© Honeywell International Inc. Do not copy without express permission of Honeywell.
b.
Allow the battery to fully charge to 100% and verify that the battery charging symbol is no
longer presented. (Battery charging may continue for a short duration even though 100% is
shown).
3)
Set the display to full-intensity by pressing the rotary knob and rotating clockwise as needed.
Press the knob again to dismiss the brightness menu.
4)
Remove power to the unit by pulling the corresponding circuit breaker and cancel the power-
down sequence by pressing the knob.
5)
Note the current time and allow unit to operate for 2 hours. At the end of the 2 hour period, if
the unit has shut-down, or on-screen parameters are Red-
X’ed, the battery must be replaced.
5.3.2
Battery Replacement Procedure
The following procedure is to be used to replace the battery pack. The battery pack consists of 4
individual cells with protection and heater circuitry all enclosed in a PVC wrapping. Two sets of leads are
present: 1) Heater Leads, and 2) Battery Power Leads.
CAUTION
DO NOT INADVERTENTLY CONNECT THE BATTERY TO THE HEATER CONNECTOR. IDENTICAL
CONNECTORS ARE UTILIZED FOR EACH. FOLLOW THE INDICATED COLOR CODING. DAMAGE TO
THE UNIT MAY OCCUR.
Figure 5-1 Li-Poly Battery Pack
Heater Leads
(Red/Red)
Battery
Leads
(Red/Black)
Polarization
Keys