____________________________________________________________________________
89000004-101
KI 300 Installation Manual
Rev 1
Page 4-7
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Figure 4-8 Unit Mounting With Tab/Slot Cutaway
5.
Push the unit toward the instrument panel until it stops against the bracket.
6.
While maintaining inward pressure, rotate the bottom such that the unit is now parallel to the
panel.
7.
Once parallel to the panel, apply downward pressure to ensure the upper tabs remain fully
engaged.
8.
While holding in-ward and down-ward pressure on the unit, tighten the lower screw with the
3/32 hex drive. Torque to 5 inch-lbs.
CAUTION
DO NOT OVER TIGHTEN
9.
Verify that the unit is firmly attached and completely parallel to the instrument panel. (The
bezel of the unit will stand-off slightly from the instrument panel, which is normal.)
4.7
System Configuration
The following section provides instructions for initial setup configuration of the KI 300. For complete
operation guide, including normal and abnormal operation, see the Pilot Guide (PN 89000004-201).
4.7.1
Initial Power On
Upon normal power-on, the unit will display the company logo, battery status and software version as
follows: