59
Appendix H
Appendix H
How to Read Key System Indicators and Reset Alignment Values
Read System Key Indicators (Confi guration)
1. Start Bendix
®
ACom
®
Diagnostics and connect to vehicle.
2. Select “Advanced” and Click “Start with ECU” to display the “Advanced Status” window.
3. Select “Confi g” to display the indicators
Take Note of:
Model #,
Software Version,
Software P/N,
Active DTCs
System Key Indicators
Attribute
Description
See Section:
Mounting Offset
This value should equal 0 if the radar sensor is mounted on the center line of the vehicle.
If the service technician believes the radar sensor should be mounted offset from center,
call 1-800-AIR-BRAKE (1-800-247-2725, option 2).
6.2
Stationary Object
Warning Indicator
This is a status indicator for the function of stationary object warning. Available for use
in Bendix
®
Wingman
®
Advanced
™
system versions since 2010.
1.7
Lateral Alignment
Value
Trouble code will be set if
value is less than -1.5º
Normal operation
-1.5º to 1.5º
Trouble code will be set if
value is more than 1.5º
6.8
Confi guration
Number
This indicates the distance setting and following distance alert that are confi
gured for
the vehicle. Refer to
Table 7
for setting information.
5.4
How To Reset The (Lateral) “Alignment Value”
4. From the confi guration window shown above, click “Modify.”
5. From the Change Confi guration window, select “Reset Alignment Value.”
6. Cycle the vehicle ignition power to complete the process.
Call the Bendix Tech Team at 1-800-AIR-BRAKE (1-800-247-2725, option 2) for troubleshooting assistance.
Содержание Wingman FLR20
Страница 31: ...31 FIGURE 22 TYPICAL WINGMAN ADVANCED VEHICLE REPORT...
Страница 62: ...62 NOTES...