[8] ADJUSTMENT OF THE BALANCE ARM
8-1. Adjustment of the tension of the balance arm
Position the angle of the balance arm so the tension adjustment nut becomes visible just under slot A.
Turn the nut and adjust the tension with the adjustment bar supplied with the light.
Adjustment Bar
Socket Screw
Tension Adjustment Nut
Slot A
(for tension)
Slot B
(for angle)
Tension Adjustment Nut
Hole A
8-2 Adjustment of the angle of the light head
(1) Use a 2mm hex key wrench to loosen socket screw in front of Slot B.
(2) Position the angle of the balance arm so the head angle adjustment nut becomes visible just under the slot B.
Turn the nut and adjust the tension with the adjustment bar supplied with the light.
Note : Adjusting the head without loosening the socket screw will damage the arm.
When the light head tilts downward,
turn the nut to - direction.
When the light head tilts upward,
turn the nut to + direction.
Direction of rotation of the nut
When the light head tends to go up, turn the nut to + direction.
When the light head tends to go down, turn the nut to – direction.
Direction of rotation of the nut
(3) After adjustment is done, re-tighten the socket.
Note : Unless this socket screw is re-tightened, the angle of the head will be changed during use.
-8-