ISS 7, SECTION 573-115-700
3. 41
Print Suppression and Offline Stunt Shift Control Mechanism
(A) SUPPRESSION CODE BAR POSITION
REQUIREMENT
NOTCHES IN SUPPRESSION CODE BAR SHOULD ALIGN WITH NOTCHES IN OTHER
CODE BARS. VIEW FROM REAR OF UNIT ABOVE STUNT BOX. GAGE BY EYE.
TO CHECK
ENERGIZE THE PRINT SUPPRESSION MAGNET AND PLACE ALL CODE BARS IN
SPACING POSITION.
TO ADJUST
OPERATE MAGNET ARMATURE MANUALLY OR ELECTRICALLY. PLACE ALL CODE BARS
IN SPACING POSITION. PIVOT THE ARMATURE EXTENSION IN ITS ELONGATED
MOUNTING HOLE WITH THE MOUNTING SCREWS LOOSENED.
MOUNTING
YOKE
PRINT SUPPRESSION
MAGNET
TOP VIEW LEFT SIDE
ARMATURE EXTENSION
(B) TYPE BOX CLUTCH TRIP LEVER
SEE PAR .
2.22
AND REFINE
REQUIREMENT TO
MIN.
0.040
INCH
MAX.
0.055
INCH
(C) TYPE BOX
ARM
(E) PRINT SUPPRESSION MAGNET ARMATURE RETURN SPRING
REQUIREMENT
MIN.
7
OZS.
MAX.
10-1/2
OZS.
TO START MAGNET ARMATURE MOVING TOWARD CORE
TO CHECK
PRINT SUPPRESSION MAGNET UNOPERATED
SEE PAR.
3.14
'�""�
(D) BLOCKING BAIL
SEE PAR.
3.14
NOTE: KEEP POLE FACE FREE
OF OIL AND GREASE.