Your device is now ready for operation and works with the basic functions.
1
1
22..
PPuullssee ooppeerraattiioonn
In addition to the radio system, the gate drive operator can also be controlled
via pushbuttons, key switches or coding switches. The potential-free connec-
tion is made via terminals 8 and 9 (pulse).
1133..
AAddddiittiioonnaall ffuunnccttiioonnss
The modern electronics are equipped with numerous additional functions that
can be activated and are described below.
13.1.
Overview of coding switches for additional functions
There are two coding switches on the motor control.
1.
Program selector switch (DIP switch) 1-8
S1.1 / S.1.2 Length soft outlet
1 OFF
2 OFF
normal
1 ON
2 OFF
short
1 OFF
2 ON
long
1 ON
2 ON
in the closing run off
in up-run short
S1.3
Automatic closing me-
chanism
ON
= active
= inactive
OFF
S1.4
Partial opening
ON
= Partial opening position taught
= Don´t teach partial opening
position
OFF
S1.5
Warning light
ON
= 5 Sec. warning time
= only active when the engine is
running
OFF
S1.6
Running speed
OFF
= normal
=
half speed (open & close)
ON
S1.7 / S1.8
Impulse - Function
S1.7
= OFF
S1.8
= OFF
S1.7
= ON
S1.8
= OFF
Targeted open / close
without panic function
S1.7
= OFF
S1.8
= ON
Dead-man mode
S1.7
= ON
S1.8
= ON
19
Note:
Zu S1.3:
In the case of automatic closing, there is a 5 second pre-
warning. If the prewarning time is not activated (S1.5 = off),
the prewarning is also given via a flashing light output.
Zu S1.5:
A self-flashing warning light is required.
Zu S1.7/S1.8:
In dead-man mode, the automatic closing function is not ef-
fective. Safety inputs must be provided with be provided
with bridges.
13.2.
Safety switch (DIP switch) 1+2
S2.1
Entrance LS / SE1
ON =
8k2 Safety edge
Main closing edge
OFF =
Light barrier
S2.2
Entrance LS / SE2
ON =
8k2 Safety edge
Secondary closing
edge
OFF =
Light barrier
1144..
CChhaannggee ssoofftt ssttoopp
The running distance of the soft stop can be varied with DIP switches 1 and 2:
1 OFF
2 OFF
Normal soft stop
1 ON
2 OFF
Short soft stop
1 OFF
2 ON
Long soft stop
1 ON
2 ON
soft stop only in "OPEN" direction
1 2