15
TLX Matrix Switch Interfaces
thinklogical
Rev. H
–
Jan. 2019
17600
– System Data
System data consists of 6 bytes. The first byte has the current alarm contact settings. Bit
0 (lsb) is the bit for the Power Supply alarm, and bit 3 is the bit for the 'any' alarm. The
next byte is for the installed card inventory. A '0' bit means the card is installed and a '1'
bit means the card is removed. The other bytes are for internal use.
ALARMS
INVENTORY
BIT
Byte 0
Byte 1
0
Alarm 1
Card 1
1
Alarm 2
Card 2
2
Alarm 3
Card 3
3
Alarm 4
4
5
6
7
Table 3: TLX48 System Data
17601:17603
– Card Data
Each I/O card in the Matrix Switch has an associated TCP port. Card 1 uses port 17601, card 2
uses 17602, and so on. The data is formatted as follows:
•
12 bytes, internal use
•
1 byte, card type (other card types may be added in the future)
▪
0xff
missing
▪
0x02
normal
▪
0x05
reclocked
▪
0x0c
HDMI
▪
0x0a
10 Gig
▪
0x0b
CATx
•
SFP data, 256 bytes per SFP, 16 SFPs per card
▪
128 bytes, SFP ID data
▪
128 bytes, SFP diagnostic data
Содержание thinklogical TLX160
Страница 1: ......