background image

 

 

 

TLX Matrix Switch Interfaces

 

thinklogical

 

Rev. H 

 Jan. 2019

 

 

About this Manual 

This  document  describes  the  serial  and  network  interfaces  for  Thinklogical's

®

  TLX  family  of 

Matrix Switches.  

Note and Warning Symbols 

Throughout  this  manual  you  will  notice  certain  symbols  that  bring  your  attention  to  important 
information. These are 

Notes

 and 

Warnings

. Examples are shown below. 

Note: Important Notes appear in blue text preceded by a  yellow exclamation point 
symbol, as shown here. 

note

 is meant to call 

the reader’s attention to 

helpful or important

 information at a point in 

the text that is relevant to the subject being discussed. 

Please read this information thoroughly

Warning! 

All Warnings appear in red text, followed by blue text, and preceded by a 

red stop sign, as shown here.

 

warning

 

is meant to call the reader’s attention to 

critical

 information at a point in the text that 

is relevant to the subject being discussed. 

Please read this information thoroughly

 

Font Conventions Used in this Document 

The following fonts and colors are used throughout this document to help differentiate between 
file  names,  commands,  outputs  and  document  names  (lower  &  upper-case  letter 

o

  and 

zero

shown right): 

 

 

 

Filenames  

 

 

 

Font: Courier New - 35-35-220  

oO0 

Linux Command Entered by the User  Font: Consolas - 196-89-17 

 

 

oO0

 

Output from a Command   

 

Font: Consolas 

 0-128-128 

 

 

oO0

 

Document_Name*    

 

 

Font: Georgia 

 83-129-53   

 

 

oO0 

*

 These and other documents may be found on our web site: 

http://www.thinklogical.com/user_manuals 

Product Serial Number 

Thinklogical products have a unique serial number,  which  includes a date-code, printed on an 
adhesive label that is affixed to the unit. The format for the date-code is 

2 digits for the month

dash, 

2 digits for the year

, plus 

at least four digits for a unique unit number

. For example: 

09-

18

0129

 indicates the unit was built in the 

9

th

 month of 20

18

 and is unit number 

129

Connection to the Product 

Connections  and  installation  hardware  for  our  products  use  industry-standard  devices 
and  methods.

  All  wiring  connections  to  the  customer  equipment  are  designed  to  minimize 

proprietary or customized connectors and cabling. Power connections are made with regionally 
appropriate power cords and approved methods.  

 

 

Содержание thinklogical TLX160

Страница 1: ......

Страница 2: ...All rights reserved Printed in the U S A Thinklogical A BELDEN BRAND 100 Washington Street Milford Connecticut 06460 U S A Telephone 1 203 647 8700 All trademarks and service marks are property of th...

Страница 3: ...6 Standards with Which Our Products Comply 6 Supplementary Information 6 THE TLX SWITCH INTERFACES 7 Documentation 7 Byte Order for the Switch Connection Status Broadcast on Port 17564 7 Big Endian 7...

Страница 4: ...nd NATO NIAPC Evaluation Scheme GREEN and the U S DoD DISA JITC UCR 2013 APL information assurance standards And Thinklogical Velocity products are the first system with both KVM and video matrix swit...

Страница 5: ...he following fonts and colors are used throughout this document to help differentiate between file names commands outputs and document names lower upper case letter o and zero shown right Filenames Fo...

Страница 6: ...all required domestic and many international requirements Regulatory Compliance Thinklogical s products are designed and made in the U S A These products have been tested by a certified testing labora...

Страница 7: ...eographical regions and might not apply to your location This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la c...

Страница 8: ...e Switch Connection Status Broadcast on Port 17564 Warning The 16 bit values documented here store the most significant byte first This is called Big Endian format For example a hexadecimal value of 1...

Страница 9: ...s The primary CPU card will use address X and address X 100 The back up CPU will use address X 1 and it will take over address X in the event of a failure in the primary CPU The factory default value...

Страница 10: ...f the switch Users should use the IP address in the data to identify which switch sent the message The data in the status block is stored in big endian format This means the MSB of the data is stored...

Страница 11: ...nected Example c0 a8 0d 19 00 00 00 01 00 0c 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 12 0x000c Output 1 is connected to input 17 0x0011 Output 2 is connecte...

Страница 12: ...removed The other bytes are for internal use ALARMS INVENTORY BIT Byte 0 Byte 1 0 PS Card 1 1 Fan 2 Temp 3 Card 4 5 6 7 Table 1 TLX12 System Data 17601 Card Data The I O card in the Matrix Switch is a...

Страница 13: ...nected Example c0 a8 0d 19 00 00 00 01 00 18 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 24 0x0018 Output 1 is connected to input 17 0x0011 Output 2 is connecte...

Страница 14: ...removed The other bytes are for internal use ALARMS INVENTORY BIT Byte 0 Byte 1 0 PS Card 1 1 Fan 2 Temp 3 Card 4 5 6 7 Table 2 TLX24 System Data 17601 Card Data The I O card in the Matrix Switch is a...

Страница 15: ...nected Example c0 a8 0d 19 00 00 00 01 00 30 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 48 0x0030 Output 1 is connected to input 17 0x0011 Output 2 is connecte...

Страница 16: ...ther bytes are for internal use ALARMS INVENTORY BIT Byte 0 Byte 1 0 Alarm 1 Card 1 1 Alarm 2 Card 2 2 Alarm 3 Card 3 3 Alarm 4 4 5 6 7 Table 3 TLX48 System Data 17601 17603 Card Data Each I O card in...

Страница 17: ...8 0d 19 00 00 00 01 00 50 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 80 0x0050 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0x001...

Страница 18: ...al use ALARMS INVENTORY BIT Byte 0 Byte 1 Byte 2 Byte 3 0 Alarm 1 0 Card 1 Card 9 1 Alarm 2 0 Card 2 Card 10 2 Alarm 3 0 Card 3 Card 11 3 Alarm 4 0 Card 4 Card 12 4 Alarm 5 0 Card 5 Card 13 5 Alarm 6...

Страница 19: ...8 0d 19 00 00 00 01 01 A0 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 160 0x00A0 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0x00...

Страница 20: ...l use ALARMS INVENTORY BIT Byte 0 Byte 1 Byte 2 Byte 3 0 Alarm 1 0 Card 1 Card 9 1 Alarm 2 0 Card 2 Card 10 2 Alarm 3 0 Card 3 Card 11 3 Alarm 4 0 Card 4 Card 12 4 Alarm 5 0 Card 5 Card 13 5 Alarm 6 0...

Страница 21: ...0 a8 0d 19 00 00 00 01 01 40 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 320 0x0140 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0...

Страница 22: ...Byte 2 Byte 3 Byte 4 0 Alarm 1 0 Card 1 Card 9 Card 17 1 Alarm 2 0 Card 2 Card 10 Card 18 2 Alarm 3 0 Card 3 Card 11 Card 19 3 Alarm 4 0 Card 4 Card 12 Card 20 4 Alarm 5 0 Card 5 Card 13 5 Alarm 6 0...

Страница 23: ...0 a8 0d 19 00 00 00 01 02 80 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 640 0x0280 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0...

Страница 24: ...Alarm 2 Alarm 10 Card 4 Card 20 Card 3 Card 19 Switch 2 2 Alarm 3 0 Card 6 Card 22 Card 5 Card 21 Switch 3 3 Alarm 4 0 Card 8 Card 24 Card 7 Card 23 Switch 4 4 Alarm 5 0 Card 10 Card 26 Card 9 Card 2...

Страница 25: ...168 13 25 Chassis 0 First Port number 1 Last Port number 640 0x0280 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0x0012 Note The TXL1280 outputs status in two blocks The...

Страница 26: ...d 26 Card 34 Alarm 2 Alarm 10 Switch 2 2 Card 3 Card 11 Card 19 Card 27 Card 35 Alarm 3 Alarm 11 Switch 3 3 Card 4 Card 12 Card 20 Card 28 Card 36 Alarm 4 Alarm 12 Switch 4 4 Card 5 Card 13 Card 21 Ca...

Страница 27: ...Network Management Protocol The MIB Management Information Base definition files are located on the switch in the directory usr share snmp mibs The SNMP program may be configured by modifying the fil...

Страница 28: ...n is enabled by entries in the rsyslog configuration file etc rsyslog conf or in configuration files located in etc rsyslog d The two log files with the most interesting information are var log daemon...

Страница 29: ...lxcntl Output Ports Ports Function Program 17560 udp send LOS event tlxoobm network broadcast multicast 17564 udp send connection status tlxapi localhost only Option exists to restrict to localhost Ca...

Страница 30: ...29 TLX Matrix Switch Interfaces thinklogical Rev H Jan 2019 Log files var log api var log messages var log daemon log var log tlxoobm log var log errors log var log snmpd log...

Страница 31: ...Thinklogical is staffed Monday through Friday from 8 30am to 5 00pm Eastern Time Zone We will do our best to respond to your email inquiries promptly Please use the following email addresses info thin...

Страница 32: ...he device or if you purchased directly call Thinklogical at 1 800 291 3211 USA Return Authorization If you must return a product to Thinklogical directly please contact us at 1 800 291 3211 or 1 203 6...

Отзывы: