Installation RSR20/RSR30
Release 06 07/2021
9
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
Grounding the device
The device is grounded by the separate ground screw on the front panel.
Use a wire diameter for the ground conductor that is no smaller than
the diameter of the supply voltage connection, however of at least
0.75 mm² (AWG18).
Ground the device before connecting any other cables.
Disconnect the grounding only after disconnecting all other cables.
Shielding ground
The overall shield of a connected shielded twisted pair cable is connected
to the grounding connector on the front panel as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
Supply voltage
The supply voltage is electrically isolated from the housing.
The devices are designed for operation with safety extra-low voltage.
Connect only safety extra-low voltage circuits with voltage restrictions
in line with IEC/EN 60950-1 to the supply voltage connections and
signal contacts.
Exclusively connect a supply voltage that corresponds to the type
plate of your device.
Ground the device before connecting any other cables.
Exclusively for device variants featuring supply voltage with
characteristic value C:
The power supply is Class 2 compliant.
The power supply conforms to overvoltage category I or II.
The power supply has an easily accessible disconnecting device
(for example a switch or a plug). This disconnecting device is
clearly identified. So in the case of an emergency, it is clear which
disconnecting device belongs to which power supply cable.
The electrical wires are voltage-free.
A fuse suitable for DC voltage is located in the plus conductor of the
power supply.
The minus conductor is on ground potential. Otherwise, a fuse is
also located in the minus conductor.
Regarding the properties of this fuse:
See “General technical data” on page 53.
The wire diameter of the power supply cable is at least 0.75 mm²
(North America: AWG18) on the supply voltage input.