Installation RSR20/RSR30
Release 06 07/2021
41
Figure 6: Mounting the device on the wall
Proceed as follows:
Mount the device on the wall plate as shown in the illustration. Insert the
upper snap-in guide of the device into the rail and press it down against
the rail until it snaps into place.
Fasten the wall plate
(see on page 61 “Accessories”)
on a level wall
surface using four screws.
2.2.3
Grounding the device
Use a wire diameter for the ground conductor that is no smaller than the
diameter of the supply voltage connection, however of at least 0.75 mm²
(AWG18).
The device is grounded by the separate ground screw on the front panel.