Industrial Edge Gateway – Release 01.0.00 – 10/2022
5.2.1 Ethernet Ports
The OpEdge configuration webpage allows configuring seven Ethernet ports on the module and
assigning specific LAN configurations. Additionally, the OpEdge can be configured as a DHCP
server for end devices.
The configuration options for OpEdge Ethernet ports include speed, duplex mode, LAN
membership, and tagging.
To configure an Ethernet port on OpEdge:
1
Click the
Interfaces
tab on the OpEdge configuration webpage.
2
Under
Port Settings
, provide the following details:
Parameter
Description
Port
OpEdge Ethernet port number:
ETH1
to
ETH7
LAN Membership
LAN configuration to be assigned to the port. More information is detailed
in the
LAN Configuration
in section 5.3.2.
3
Click
A
PPLY