Installation MACH4002
Release 16 03/2021
9
cable is connected, the basic device is grounded via the power supply
connection.
Only now do you take the card out of the conductive bag.
Outside the basic device, only store the cards in a conductive ESD
protective bag.
ESD protective field equipment is available for the safe handling of
electrostatically endangered assemblies.
Further information about electrostatic sensitive modules can be found in
DIN EN 61340-5-1 (2007-08) and DIN EN 61340-5-2 (2007-08).
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
The device is grounded via the voltage supply socket.
Reduced air flow: Install the device in the switch cabinet in such a way
that ensures sufficient air flow for operating the device safely.
Keep the ventilation slits free to ensure good air circulation.
Make sure there is at least 3.94 in (10 cm) of space in front of the
ventilation slits of the casing.
Never operate the device without a plug-in fan.
Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not
touch the connection terminals.
Seal all unused slots with cover panels.
Modules, fans and power supply units of a switched-on device may
only be installed or removed by an electrician.
Fans are subject to natural wear. If one or more fans in the plug-in fan
fail, function and lifetime of a device can be negatively affected or the
device may fail completely. Use the monitoring functions of the device
for fans and temperature.
Depending on your installation conditions, it may be possible to
continue operating your device after one fan has failed. Observe the
temperature display of your device.
– In the Command Line Interface with the command: show
temperature.
– In the Graphical User Interface, in the dialog Basic settings:
System, Temperature
The displayed temperature must not exceed the maximum value of
+80 °C (+176 °F).
The basic board must not be removed.
Removing the basic board invalidates the guarantee.
The chassis should be installed in the horizontal position.
After the device is switched off, the fan blades continue rotating for a
number of seconds. Do not reach into a rotating fan!
Содержание Hirschmann MACH4002 Series
Страница 71: ...Installation MACH4002 Release 16 03 2021 71 ...
Страница 72: ......