Installation MACH4002
Release 16 03/2021
57
6.3
Interfaces
6.4
EMC and immunity
Device
Interface
Version
MACH4002-...
Signal contact
4-pin pluggable terminal block
V.24 access
1 × RJ11 socket
USB interface
for connecting an AutoConfiguration Adapter ACA22.
EMC interference
immunity
IEC/EN 61000-4-2
Electrostatic discharge
Contact discharge
Air discharge
6 kV
8 kV
IEC/EN 61000-4-3
Electromagnetic field
80 - 2,700 MHz
max. 10 V/m
IEC/EN 61000-4-4
Fast transients (burst)
- Power line
- Data line
2 kV
4 kV
IEC/EN 61000-4-5
Voltage surges
- Power line, line/line:
- Power line, line/earth
- Data line
2 kV
2 kV
4 kV
IEC/EN 61000-4-6
Line-conducted interference voltages
150 kHz - 80 MHz
10 V
EN 61000-4-9
Pulse magnetic fields
300 A/m
EMC interference
emission
EN 55032
Class A
Yes
FCC 47 CFR Part 15 Class A
Yes
German Lloyd
Classifi Construction Guidelines VI-7-3 Part 1 Ed. 2001 Yes
Stability
Vibration
IEC 60068-2-6 Test FC test level according to IEC 61131-2
Yes
Germanischer Lloyd Guidelines for the Performance of Type
Tests Part 1
Yes
Shock
IEC 60068-2-27 Test Ea test level according to IEC 61131-2
Yes