MACH 4000
Release 11/08
49
Interfaces
EMC and immunity
Network range
2.
The 0V connections within a DC module (M4-...-...VDC 300W) are connected with each oth-
er.
Interface
Design
MACH 4002-...
Signal Contact
4-pin pluggable terminal block
V.24 access
1 x RJ11 socket
USB interface
For connecting an AutoConfiguration
Adapter ACA 21-USB
EMC interference
immunity
IEC/EN 61000-4-2
Electrostatic discharge
Contact discharge
Air discharge
6 kV
8 kV
IEC/EN 61000-4-3
Electromagnetic field
80 - 2,700 MHz
10 V/m
IEC/EN 61000-4-4
Fast transients (burst)
- Power line
- Data line
2 kV
4 kV
IEC/EN 61000-4-5
Voltage surges
- Power line, line/line:
- Power line, line/earth
- Data line
2 kV
2 kV
4 kV
IEC/EN 61000-4-6
Line-conducted interference voltages
150 kHz - 80 MHz
10 V
EN 61000-4-9
Impulse-shaped magnetic fields
300 A/
m
EMC emitted inter-
ference
EN 55022
Class A
Yes
FCC 47 CFR Part 15 Class A
Yes
Germanischer Lloyd Classifi Construction Guidelines VI-7-3 Part 1 Ed.2001 Yes
Stability
Vibration
IEC 60068-2-6 Test FC test level according to IEC 61131-2
Yes
Germanischer Lloyd Guidelines for the Performance of Type
Tests Part 1
Yes
Shock
IEC 60068-2-27 Test Ea test level according to IEC 61131-2
Yes
TP port
Length of a twisted pair segment
max. 100 m (cat5e cable with 1000BASE-T)
Table 5: TP port 10BASE-T / 100BASE-TX / 1000BASE-T
Содержание HIRSCHMANN MACH 4000 Series