Remove the mains voltage supply line.
Loosen the four screws used to fasten the plug-in power unit in the basic
device and pull the unit out of the basic device, or remove the cover plate
of the power unit slot.
Slide the new plug-in power unit all the way into the basic device along
the mounting rails above and below.
Make sure that there is a good connection between the multiple plug of
the plug-in power unit and the female multipoint of the system bus.
Screw the slotted-head screws in the front panel of the plug-in power unit
flush with the frame of the basic device.
Connect the mains voltage supply line.
Note: The tightening torque is
X
7 lb in. (0.791 Nm) for input connections.
X
11 lb in. (1.243 Nm) for all field wiring terminal blocks.
2.1.6
Setting up/mounting the basic switch device in the
19" rack
Setting up
Using the basic device as a table device:
Attach the rubber feet supplied with the device to the bottom of the
device.
–First remove the protective film from the adhesive film of the rubber
feet.
–Attach one rubber foot approximately 2 cm from each corner of the
device.
Note: The adhesive surface should be free of dust and grease.
Installation
The devices are designed to be mounted in a 19" cupboard.
Make sure there is sufficient ventilation. If necessary, provide a fan for
the 19" cupboard. This will prevent the basic devices from overheating.
Measure the depth of the 19" cupboard so as to allow the mains cable,
and any power supply cables, to be fitted from the back, and the data
cables to be fitted from the front.
If you are operating the device in a 19" switch cabinet, you must install
sliding/mounting rails (not included in the delivery) to hold the weight of
the device.
Warning
If the device is installed in a 19" switch cabinet without sliding/
mounting rails, increased vibration can cause damage to the de-
vice and/or its modules.