34
MACH 4000
Release 11/08
2.1.7
Grounding the device
The device is grounded via the power supply connections.
Note: The shielding ground of the connectable twisted pairs lines is connect-
ed to the front panel as a conductor.
When the device is being operated via the 230/120 VAC power supply unit,
it is grounded via the safety plug. When it is being operated with external DC
voltage via the
M4-POWER connections, the device is grounded via the M4-POWER con-
nection.
2.1.8
Mounting the power unit chassis,
connecting it with the MACH 4000
Connect the basic switch device and the M4-POWER power unit chassis
with the mounting angle included in the delivery.
For the redundant power supply, you use the power supply cable to con-
nect the power unit(s) in the M4-POWER power unit chassis with the M4-
POWER connection on the back of the MACH 4000 device.
Warning
The power supply cables between the M4-POWER power unit
chassis and the MACH 4000 are not hot-swappable. Note the se-
quence for connecting the cables: First connect the power supply
cable(s) between M4-POWER and MACH 4000. Then connect the power
supply (AC or DC, depending on the plug-in power unit) for the M4-POWER.