MACH 4000
Release 11/08
35
Figure 9: Redundant power supply of one or more MACH 4000 devices via the M4-
POWER power unit chassis
2.1.9
Connecting the terminal block for signal contact
Figure 10: 4-pin signal contact
X
The signal contact (“FAULT”) monitors the functions of the device, thus
enabling remote diagnostics. You can specify the type of function moni-
toring in the Management.
X
You can also use the Management to switch the signal contact manually
and thus control external devices.
A break in contact is used to report the following conditions via the potential-
free signal contact (relay contact, closed circuit):
X
The failure of at least one supply voltage.
X
A continuous malfunction in the device.
4 3
4 3
M4-S-AC/DC 300W
M4-S-AC/DC 300W
MACH 4000
back side of the device
MACH 4000
back side of the device
M4-POWER
power unit chassis
back side of the device
M4-POWER
1
2
3
Step 1: Connecting the MACH 4000 device(s) to the M4-POWER
Not hot swapable
Power unit 1
Power unit 2
M4-POWER
power unit chassis
front side of the device
Example:
2 power units mounted
Not mounted
Step 2: Connecting the power supply to the M4-POWER
FAULT
RL2
RL1