Installation BAT450-F
Release 12 07/2020
41
2.3
Installing the antennas
The device has connections for external antennas. These connections are N
sockets.
Note:
Applies exclusively to LTE device variants with the antenna WWAN-A-
I-41-S-O:
You need the adapter WWAN-N-O-N-S (N plug to SMA socket). The adapter
is included in the scope of delivery for device variants with the Configuration
characteristic value "Z" and available as accessory.
On delivery, the antenna connections are sealed with transport protection
caps.
Proceed as follows:
Remove the premounted transport protection caps from the antenna
connections.
Install at least one antenna on the radio module that you would like to use.
Use the provided terminating resistors to seal unused sockets to avoid
radio signals from one radio module being received by another radio
module. The terminating resistors are included in the scope of delivery for
device variants with the Configuration characteristic value "Z" and
available as accessory.
You will find information on setting the transmit power in chapter
“Configuring the transmit power” on page 51
.
2.4
Connecting the power supply
The supply voltage is electrically isolated from the casing.
WARNING
ELECTRIC SHOCK
Before connecting the electrical wires,
always
verify that the requirements
listed are complied with.
See “Requirements for connecting electrical wires” on page 9.
See “Requirements for connecting the supply voltage” on page 9.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.