Installation BAT450-F
Release 12 07/2020
9
The overall shield of a connected shielded twisted pair cable is connected
to the ground connection on the metal housing as a conductor.
Requirements for connecting electrical wires
Before connecting the electrical wires,
always
verify that the
requirements listed are complied with.
Requirements for connecting the supply voltage
The following requirements apply without restrictions:
The electrical wires are voltage-free.
The cables used are permitted for the temperature range of the application case.
Relevant for North America:
The power supply cables are suitable for ambient air temperatures of at least +167 °F
(+75 °C). The power supply cable wires are made of copper.
Table 1:
Requirements for connecting electrical wires
Prerequisites:
All variants
All
of the following requirements are complied with:
The supply voltage corresponds to the voltage specified on the type
plate of the device.
The power supply conforms to overvoltage category I or II.
The power supply has an easily accessible disconnecting device (for
example a switch or a plug). This disconnecting device is clearly
identified. So in the case of an emergency, it is clear which
disconnecting device belongs to which power supply cable.
The cross-section of the ground conductor is the same size as or
bigger than the cross-section of the power supply cables.
The power supply cable is suitable for the voltage, the current and the
physical load. Hirschmann recommends a wire diameter of
0.25 mm² (AWG24) to 0.75 mm² (AWG19).
Only for device
variants featuring
supply voltage with
characteristic
value W (24 V DC):
The following requirements apply alternatively:
Alternative 1
The power supply complies with the requirements
for a limited power source (LPS) as per EN 60950-1.
Alternative 2
Relevant for North America:
The power supply complies with the requirements
according to NEC Class 2.
Alternative 3
All
of the following requirements are complied with:
The power supply complies with the
requirements for a safety extra-low voltage
(SELV) as per IEC/EN 60950-1.
A suitable fuse is located in the plus conductor
of the power supply.
Regarding the properties of this fuse:
See “General technical data” on page 58.
Only for device
variants featuring
supply voltage with
characteristic
value N (110 V DC):
A fuse suitable for DC voltage is located in the plus conductor of the power
supply.
Regarding the properties of this fuse:
See “General technical data” on page 58.
Table 2:
Requirements for connecting the supply voltage
Содержание HIRSCHMANN BAT450-F
Страница 54: ...54 Installation BAT450 F Release 12 07 2020 To save the value click the Send button...
Страница 95: ...Installation BAT450 F Release 12 07 2020 95...
Страница 96: ...96 Installation BAT450 F Release 12 07 2020...
Страница 97: ...Installation BAT450 F Release 12 07 2020 97...
Страница 98: ......