Installation BAT450-F
Release 12 07/2020
43
2.5
Operating the device
2.5.1
Connecting the power supply
Supply voltage with the characteristic value W (24 V DC)
You start up the device by connecting the power supply via the 8-pin, “X”-
coded M12 socket for PoE port or via a 5-pin, “A”-coded M12 socket.
You find the prescribed tightening torque of the locking screw in chapter:
“General technical data” on page 58
Only connect the device to a PoE network indoors.
Only run data links indoors (IEEE 802.3 area A).
Supply voltage with the characteristic value N (110 V DC)
You start up the device by connecting the power supply via the 4-pin, “A”-
coded M12 socket.
You find the prescribed tightening torque of the locking screw in chapter:
“General technical data” on page 58
2.6
Connecting data cables
Connect the data cables according to your requirements.
You find the prescribed tightening torque of the locking screw in chapter:
“General technical data” on page 58
WARNING
ELECTRIC SHOCK
Before connecting the electrical wires,
always
verify that the requirements
listed are complied with.
See “Requirements for connecting electrical wires” on page 9.
See “Requirements for connecting the supply voltage” on page 9.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
Содержание HIRSCHMANN BAT450-F
Страница 54: ...54 Installation BAT450 F Release 12 07 2020 To save the value click the Send button...
Страница 95: ...Installation BAT450 F Release 12 07 2020 95...
Страница 96: ...96 Installation BAT450 F Release 12 07 2020...
Страница 97: ...Installation BAT450 F Release 12 07 2020 97...
Страница 98: ......