About Updating the HAD FPGA
Update the HAD FPGA
The HAD FPGA update can be performed using either a serial console
attached to the front edge of the Controller board using the DB9 connector
or a Telnet session.
CAUTION
It is recommended that HAD (Host Address Decoder) FPGA (Field Program-
mable Gate Array) updates are performed by qualified personnel only, i.e. an
EIC (Engineer In Charge).
Update the HAD FPGA Using a Serial Console
1.
Open the Frame door and attach the serial console cable to the front
edge of the Controller board (see the version 8.0 Installation & Service
Manual for your K-Frame model for more information).
2.
Verify and/or set the serial parameters to:
115200 baud
8 data
no parity
1stop
3.
To check the HAD status, enter checkHADs at the prompt:
->checkHADs
Result:
HADs up-to-date:
value = 1 = 0x1
HADs out-of-date:
value = 0 = 0x0
4.
Enter the console menu by typing consoleMenu at the prompt:
->consoleMenu
Result:
Figure 9. Console Menu
5.
Enter the number nine [9] for the Debug menu, at the prompt:
->9
Result: