53
Kaleido-Modular-X
Hardware Description & Installation Manual
Replacing the frame ventilation fan in a Densité 3+ FR4 frame
To replace the frame ventilation fan in a Densité 3+ FR4 frame
1 Remove the two screws (top left and bottom right corners) that secure the fan
assembly to the frame, and pull the fan assembly straight out of the frame.
Retain the screws, as they will be used to install the replacement fan assembly.
2 Slide the new fan assembly into the opening on the rear panel, pushing it straight in,
and ensuring that the connector on the assembly mates with the socket in the frame.
3 Use the two screws you retained from the old fan, to secure the new fan assembly to
the rear panel.
Replacing the Air Filter
You may remove the air filter for cleaning or replacement.
To remove the air filter in a Densité 3 or Densité 3+ FR1 frame
1 Open the front panel of the frame (see
2 Grasp the top of the filter installed on the rear of the door, and pull it gently out of its
mounting slot.
To install a filter in a Densité 3 or Densité 3+ FR1 frame
1 Slide the filter into the slot at the bottom of the front panel door, and ensure that the
filter is not bunched or folded.
2 Close the front panel of the frame (see
To remove the air filter in a Densité 3+ FR4 frame
1 Open the front door of the frame (see
2 Lift the door up to slide it off the hinge pins, and lay it face down on a work surface.
3 Undo the captive thumbscrew at one end of the filter retaining bar.
4 Slip the other end of the retaining bar out of its slot.
5 Pull the filter away from the faceplate, by slipping it off the retaining hooks at the four
corners.