background image

Document Part # 026-4158 Rev 1 11-JAN-2017

Page 1 of 5

©2017 Emerson Climate Technologies Retail Solutions, Inc. This document may be photocopied for personal use. 
Visit our website at http://www.emersonclimate.com/ for the latest technical documentation and updates.

The Site Supervisor Display (P/Ns 818-9022 and 818-9023) is a remote user interface for the Site Super-

visor (P/N 860-1200) that connects to the controller using RS485 network to Serial Port D, and shows a sim-
plified UI that allows users to perform critical actions in the controller quickly and easily such as overriding 
lights, heating and cooling stages, viewing alarms, and status information.

General Warnings and Safety Precautions

• This guide is part of the product and should be kept near the instrument for quick and easy reference.
• The Display should not be used for purposes different from those described in this guide. It cannot be used as a safety 

device.

• Check the application limits before proceeding.
• Emerson Retail Solutions reserves the right to change the composition of its products, even without notice, ensuring the same and unchanged functionality.
• When using an external power supply, it is necessary to separate the power of the device from the rest of the electrical devices connected inside the electrical 

panel. The secondary of the transformer must never be connected to earth ground.

• Disconnect all electrical connections before any kind of maintenance is performed. Do not open the Site Supervisor Display.
• Check that the supply voltage is correct before connecting.
• Do not expose to water or moisture: use the controller only within its operating limits to avoid sudden temperature changes with high atmospheric humidity to 

prevent condensation.

• Wire polarity must be observed: A wrong connection may cause possible malfunctioning and damage to the controller or Display.

Panel Mounting

      

   

Site Supervisor Display

Installation Guide

Содержание 818-9022

Страница 1: ...om those described in this guide It cannot be used as a safety device Check the application limits before proceeding Emerson Retail Solutions reserves the right to change the composition of its products even without notice ensuring the same and unchanged functionality When using an external power supply it is necessary to separate the power of the device from the rest of the electrical devices con...

Страница 2: ...lay base as a template 3 Move the base out of the way and drill the mounting holes If the mounting holes are too large and do not allow the base to be tightened securely use the plas tic screw anchors to secure the base 4 Fasten the base snugly to the wall using the mount ing holes shown in the figure above and two mount ing screws Leveling is for appearance only and will not affect Display operat...

Страница 3: ...updates Electrical Connections Observe the connection polarity of the Display A wrong connection can cause malfunctioning and possible damage to the controller or the Dis play An external power supply is necessary to separate the power of the device from the rest of the electrical devices connected inside the electrical panel The secondary of the transformer must never be connected to earth ground...

Страница 4: ...datefile Select the file and click Open or double click the file to load 6 A Loading file message will appear wait for several seconds Once loaded the Revision and File Size will display 7 Click Upgrade A progress bar will appear with the percentage completed The system will reboot and restart automatically when the upgrade is complete Note that both the Display and Site Supervisor firmware will b...

Страница 5: ...erson Climate Technologies Retail Solutions Inc All rights reserved Document Part 026 4158 Rev 1 11 JAN 2017 Page 5 of 5 Technical Data Housing Self extinguishing ABS Mounting Panel mounting or wall mounting Frontal IP Protection IP54 without UR NTC sensor UL Type 1 enclosure Rear IP Protection IP20 Pollution Degree 2 Impulse Voltage Overvoltage category II Connections Type Panel version Pitch 5mm...

Отзывы: