background image

72

Operation

KMX-3901-OUT Output Settings Panel

The navigation area contains buttons that control the contents of the main area.

• Click a button to access the associated features.

• Click the left side border (identified by a small arrow icon) to hide or reveal this area.

The operating control area contains the main operating controls for managing the Kaleido-
Modular-X multiviewer’s feature set. The contents change depending on the button you 
clicked in the navigation area. The relevant panels are described individually in the 
following sections:

KMX-3901-OUT Output Settings Panel

, on page 72

KMX-3901-OUT Network Settings Panel

, on page 74

IPG-3901 Network Config Panel

, on page 75

IPG-3901 Gateway Config Panel

, on page 76

Info Panel

, on page 78

KMX-3901-OUT Output Settings Panel

Set the resolution of the multiviewer output heads to an appropriate value based on the 
displays in use. If a display uses EDID (Extended Display Identification Data) to 
communicate its characteristics to the Kaleido-Modular-X multiviewer via the HDMI 
connector, the matching can be done automatically, in which case the detected resolution 
appears in the 

Detected resolution

 box. Select the check box to use the detected 

resolution. If the detected resolution is not used (either because the check box is not 
selected or because the display does not make the information available) the value 
selected in the 

Output resolution

 list will be used.

Содержание Grass Valley Kaleido-Modular-X

Страница 1: ...Hardware Description Installation Manual M933 9802 111 2017 02 01 KALEIDO MODULAR X HIGH PICTURE COUNT ULTRA FLEXIBLE AND SCALABLE MULTIVIEWER...

Страница 2: ...uct manuals for their own internal business use Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and r...

Страница 3: ...es lectrostatiques DES Une d charge lectrostatique peut se produire lorsque des composants lectroniques ne sont pas manipul s de mani re ad quate ce qui peut entra ner des d faillances intermittentes...

Страница 4: ...liance O GB T 26572 2011 O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in GB T 26572 2011 Note This equi...

Страница 5: ...11 Grass Valley Grass Valley Technical explanations This statement is based on the information provided by our suppliers of components and collected through our Grass Valley s environmental management...

Страница 6: ......

Страница 7: ...rd 47 Replacing a GPI 1501 Card 48 Replacing Power Supply Modules 49 Replacing Frame Ventilation Fans 51 Replacing the Air Filter 53 2 Operation 55 LED Interface 56 KMX 3901 IN Input Card Interface 56...

Страница 8: ...ntrol 84 Electrical 84 Physical 85 KMX 3901 IN 4K UHD Prescaler Cards 86 KMX 3901 IN IP Input Output Cards 87 IP Communications 87 Video Inputs Over IP 87 Video Inputs Over SDI 88 FlexBridge Inputs Ou...

Страница 9: ...additional input or output modules housed in a different frame Install the input stage next to the router and the output stage next to the displays to eliminate the HDMI extenders More robust than cas...

Страница 10: ...3901 IN IP input output modules with two FlexBridge connectors for bridging to KMX 3901 OUT output heads are also available Two FlexBridge connections per KMX 3901 OUT are required Seamless control ac...

Страница 11: ...s and 2 outputs Kaleido Modular X configuration with 16 inputs and 2 outputs Kaleido Modular X configuration with 32 inputs and 4 outputs Kaleido Modular X configuration with IP inputs 2 IP outputs an...

Страница 12: ...with 48 inputs and 4outputs SDI Input module parts Description KMX 3901 IN 8 D 8 input HD SD SDI and 3 Gbps input module with dual FlexBridge outputs This card s revisions 300 310 and 400 are not full...

Страница 13: ...307 and 400 are not fully compatible with the Densit 3 FR4 frame see Notes on page 19 KMX IN 8 OPT 3GBPS license required for 3 Gb s KMX 3901 IN IP D 3 TRP Triple rear connector panel Compatible with...

Страница 14: ...he Kaleido Modular X System Kaleido Modular X functional block diagram KMX 3901 IN input modules KMX 3901 IN 8 D KMX 3901 IN 16 D and KMX 3901 IN 16 Q Kaleido Modular X functional block diagram KMX 39...

Страница 15: ...FR1 frame interface When the frame door is closed the status LED on each of the cards in the frame is visible via a light pipe in the door No other controls or indicators are present Front of Densit...

Страница 16: ...al operational elements See KMX 3901 IN Input Card Interface on page 56 KMX 3901 IN IP Input Output Card Interface on page 59 4K UHD Prescaler Card Interface on page 59 and KMX 3901 OUT Output Card In...

Страница 17: ...w of the interface on the right side of a KMX 3901 IN IP input output module Summary view of the interface on a KMX 3901 OUT output card edge Status LED Select button Power LED ABT LED REF LED SDI LED...

Страница 18: ...audio mating connectors for each output card 2 serial port adapters 1 with straight cabling and 1 with crossover cabling see RS 422 connection diagram on page 24 for every output card ordered with a...

Страница 19: ...Start Guide for your multiviewer model and some ancillary documents e g welcome letters warranty cards are distributed in printed form You can obtain the latest version of the Kaleido X User s Manual...

Страница 20: ...the frame and exhaust it to the rear Ventilation slots in the front panel allow air to flow into the frame and an air filter is mounted in the frame door The frame mounted fans are supplemented by th...

Страница 21: ...3 for details Densit 3 FR1 fan speed control On the Densit 3 FR1 frame s rear panel a slider switch beside the controller side fan allows the speed of the two rear panel fans to be specified by the us...

Страница 22: ...can be installed in a Densit 3 Densit 3 FR1 Densit 3 FR4 or Densit 3 mini frame to be part of a Kaleido Modular X multiviewer system Within a Kaleido Modular X system an output card can be designated...

Страница 23: ...two locations on the rear panel see KMX 3901 OUT D 3DRP rear panel connections below and KMX 3901 OUT D 3 SRP rear panel connections on page 25 on the front card edge see KMX 3901 OUT front card edge...

Страница 24: ...e scan SDI OUT 1 SDI OUT 2 DIN 1 0 2 3 Serial digital HD output signal for monitoring purposes ANALOG OUT 1 L ANALOG OUT 2 L WECO Analog audio output left channel to feed the audio monitoring system A...

Страница 25: ...with the second head is NOT enabled if your output card is the single head model KMX 3901 OUT S A software option is available to enable the second head KMX 3901 OUT D 3 SRP rear panel Note The two R...

Страница 26: ...nection carrying a 3G SDI signal which contains the mosaic from the input cards without graphical elements i e no audio meters no UMDs etc MV OUT 1 MV OUT 2 HDMI High definition connection for the mul...

Страница 27: ...ds for two or four possible multiviewer outputs A KMX 3901 IN IP input output card is available with two 1 1 redundant 10 GigE ports supporting up to 6 SMPTE ST 2022 6 IP video inputs 3G HD SD This in...

Страница 28: ...include two 1 1 redundant 10 GigE ports 1 ABT MADI audio input 1 LTC input 1 reference input 2 FlexBridge inputs 2 FlexBridge outputs and 2 SDI input connectors for the SDI mosaic outputs from head 1...

Страница 29: ...l plant FLEXBRIDGE IN1 FLEXBRIDGE IN2 DIN 1 0 2 3 Connections carrying the 3G SDI signals which contains the mosaic without graphical elements i e no audio meters no UMDs etc from an upstream input ca...

Страница 30: ...30 Installation Input Cards KMX 3901 IN 16 D 3QRP rear panel KMX 3901 IN 16 D 3 DRP rear panel...

Страница 31: ...ABT MADI IN DIN 1 0 2 3 Multiplexed audio from an external device e g MADI multiplexer or Audio Bridge Terminal LTC IN DIN 1 0 2 3 Time code input REF IN DIN 1 0 2 3 Reference signal to genlock the m...

Страница 32: ...m any upstream input cards and the current input card for two heads of the system FLEXBRIDGE IN B1 FLEXBRIDGE IN B2 DIN 1 0 2 3 Connections carrying the 3G SDI signals which contains the mosaic withou...

Страница 33: ...33 Kaleido Modular X Hardware Description Installation Manual KMX 3901 IN M3 D 3 DRP rear panel KMX 3901 IN M3 Q 3PRP rear panel KMX 3901 IN M3 Q 3 DRP rear panel...

Страница 34: ...meters no UMDs etc from an upstream input card for two heads of the system FLEXBRIDGE OUT A1 FLEXBRIDGE OUT A2 DIN 1 0 2 3 Connections carrying the 3G SDI signals which contains the mosaic without gra...

Страница 35: ...76 router frame its backplane is upside down and the ordering of its ports differs from when the backplane is installed in the upper bays right side up of an NV8576 frame Notice that router outputs 1...

Страница 36: ...utput signal come from video input 1 for head 1 and from video input 5 for head 2 Connector Description 3G HD SD IN 1 Link 1A Top left quadrant of 4K UHD signal A 3G HD SD IN 2 Link 2A Top right quadr...

Страница 37: ...rear panel for 4K UHD prescaler Connectors used on KMX 3901 IN 16 Q 3 DRP rear panel for 4K UHD prescaler Prescaled signal B output Prescaled signal A output 4K UHD signal A inputs 4K UHD signal B in...

Страница 38: ...available from the Documentation Library section of Grass Valley s website for more information Refer to the Kaleido X User s Manual for detailed instructions on configuring a GPI 1501 within your mul...

Страница 39: ...frame is fastened in place by two captive thumbscrews one at each end of the door The door is attached to the frame by guides that slide out of the frame as the door is pulled and allow the door to be...

Страница 40: ...se until they release and then pull the door away from the front of the frame To open the door of a Densit 3 FR4 frame Turn the thumbscrew counterclockwise until it releases and then pull the door ope...

Страница 41: ...nstalled with the frame power on Each card has a connector which plugs into the frame s backplane for distribution of power and connection to the controller card and one or two connectors depending on...

Страница 42: ...42 Installation Replacing Cards 3 Position the new panel and secure it in place with the captive screws at the bottom Rear panel installation Densit 3 frame Rear panel installation Densit 3 FR4 frame...

Страница 43: ...sition the new panel and secure it in place with the captive screw Removing a card To remove a card 1 Open the front door of the frame see Opening the front door on page 40 2 Tilt the swivel handle on...

Страница 44: ...d be inserted two slots to the left of the rightmost slot e g if the rear panel covers slots 11 15 insert the card itself at slot 13 In a Densit 3 frame output cards must be installed with a double wi...

Страница 45: ...it frame s local control panel 2 On the local control panel press the button CONFIG appears on the LCD display 3 Press the SEL button 4K UHD PRESCALER appears on the LCD display 4 Press the SEL button...

Страница 46: ...ar X system includes 4K UHD prescaler cards these must be upgraded individually after you have upgraded your system by the usual method To upgrade your system s 4K UHD prescaler cards 1 Upgrade your K...

Страница 47: ...slide out so that it can be gripped properly 2 Pull gently until the card is released from the rear connector and then slide the card out of the frame 3 Slide the new card into the controller slot an...

Страница 48: ...system to ensure proper ventilation see Closing the front door on page 41 Replacing a GPI 1501 Card In a Densit 3 FR1 frame the GPI 1501 card is located in a special slot on the upper right hand side...

Страница 49: ...ion by turning the captive screw mounted on the lower front of the power supply clockwise This engages a retaining spring which holds the supply securely in place 7 Replace the controller card 8 Close...

Страница 50: ...of the supply 3 Slide the power supply out of the frame by pulling on the bracket on the bottom right of the supply 4 Slide the new power supply module into the slot and push it gently into position t...

Страница 51: ...two different fan units for this product While they are electrically equivalent they have slightly different dimensions The fan is installed with two screws located on opposite corners The mounting pl...

Страница 52: ...the frame The two ventilator fans are mounted at different angles as shown in the above figure 3 Align the circuit board on the fan assembly with the notches in the edge of the rear panel opening see...

Страница 53: ...or replacement To remove the air filter in a Densit 3 or Densit 3 FR1 frame 1 Open the front panel of the frame see Opening the front door on page 40 2 Grasp the top of the filter installed on the re...

Страница 54: ...2 Slip the holes in the four corners of the filter over the hooks on the door panel 3 Insert the tip of the retaining bar into the slot on the hinge end of the door 4 Tighten the thumbscrew on the oth...

Страница 55: ...net port refer to the Kaleido X User s Manual Grass Valley s iControl system can be used to access the card s operating parameters from a remote computer using a convenient graphical user interface se...

Страница 56: ...evere error conditions If the Status LED is blinking orange it means that the card is selected for local control using the Densit frame s control panel or that the card is booting up See Using the Den...

Страница 57: ...on the KMX 3901 IN input cards REF LED This LED monitors the status of the REF input on the KMX 3901 IN input cards Boot status LED 1 Monitors the status of the firmware LED Meaning Green OK OFF Fail...

Страница 58: ...dge input LEDs KMX 3901 IN input cards have 2 or 4 LEDs depending on card model monitoring the status of the FlexBridge inputs located on their rear connector panel LED Meaning Green HD SDI or 3G SDI...

Страница 59: ...rface on the right side of a KMX 3901 IN IP input output module 4K UHD Prescaler Card Interface When a KMX 3901 IN 16 Q card operates as a 4K UHD prescaler its SDI LEDs 3 4 7 8 11 12 15 and 16 are alw...

Страница 60: ...for local control using the Densit frame s control panel or that the card is booting up See Using the Densit Frame Control Panel on page 63 for details If the Status LED is steady red not blinking use...

Страница 61: ...the status of the firmware during the startup process LED Meaning Green OK OFF Failure of an on board PSU or there was a glitch on the 3 3V PSU in which case reseating the card may resolve the problem...

Страница 62: ...901 OUT output cards have 2 or 4 SFP LEDs depending on rear model located on their rear connector panel These LEDs are always OFF and currently not relevant LED Meaning Green HD SDI or 3G SDI signal d...

Страница 63: ...en be blinking orange Press the CONTROLLER button on the control panel to select the controller card itself CPU ETH3 Local Control Panel In the case of a Densit 3 FR4 frame the local control interface...

Страница 64: ...essed or touched and the 30 second timeout occurs the parameters will be confirmed as if the SEL button had been pressed or touched Note The KMX 3901 IN IP input modules comprise two cards a KMX 3901...

Страница 65: ...the item and not the text shown above KMX 3901 OUT output card local menu STATUS CARD STATUS CARD VERSION RESOLUTION HEAD1 List of resolutions current HEAD2 List of resolutions current LINK STATE FANS...

Страница 66: ...hown above The SFP ports are not yet supported OFF SFP OUT 4 ON OFF FACTORY DEFAULT RESTORE CARD VERSION Kaleido Modular X 4K UHD prescaler local menu STATUS CARD STATUS CARD STATUS OFF INPUT STATUS 1...

Страница 67: ...SS 00 00 00 00 00 00 ETH2 LINK STATUS LINK UP LINK DOWN MAC ADDRESS 00 00 00 00 00 00 GATEWAY SDI IN 1 ACTIVE INACTIVE DISABLED video format at MV OUT 1 SDI IN 2 ACTIVE INACTIVE DISABLED video format...

Страница 68: ...R 5 SAVE DEFAULT USER 2 USER 3 USER 4 USER 5 NETWORK CONFIG ETH1 IP ADDRESS MASK GATEWAY ETH2 IP ADDRESS MASK GATEWAY SYSTEM SCAN RATE 50 25Hz 59 94 29 97Hz TEST PATTERN FORMAT 1080i 720p SD FORCE ALL...

Страница 69: ...deo format at MV SDI IN 2 OFF SDI IN OUT 3 ON Enables a test pattern in the selected video format at MV SDI IN 3 OFF SDI IN OUT 7 ON Enables a test pattern in the selected video format at MV SDI IN 7...

Страница 70: ...bout setting up and operating iControl In iControl Navigator iControl Web or iControl Solo double click the icon for a Kaleido Modular X input or output card KMX 3901 OUT KMX 3901 IN 8 D KMX 3901 IN 1...

Страница 71: ...indicates that the card is available for remote control from the service control panel in iControl A yellow icon indicates that someone is controlling the card from the control panel on the housing f...

Страница 72: ...ork Settings Panel on page 74 IPG 3901 Network Config Panel on page 75 IPG 3901 Gateway Config Panel on page 76 Info Panel on page 78 KMX 3901 OUT Output Settings Panel Set the resolution of the multi...

Страница 73: ...olution Format name Refresh rates Hz 1024 768 XGA 50 00 59 94 1280 720 Margay 50 00 59 94 1280 768 WXGA 50 00 59 94 1280 1024 SXGA 50 00 59 94 1280 1024 BARCO 59 94 1360 768 NEC 50 00 59 94 1480 1200...

Страница 74: ...f the KMX 3901 OUT output cards not to the Ethernet ports at the back of the Densit controller card On all Grass Valley multiviewers the network adapters are set to auto negotiate By default the conne...

Страница 75: ...e on the IPG 3901 module s Network Config panel under the Settings tab You may need to consult your network administrator to get the correct values Type the appropriate IP address mask and gateway inf...

Страница 76: ...ed and then clear the check box in the En column for every gateway you do not wish to use For example if you do not wish to stream the mosaic output at all clear the check boxes for both MV OUT 1 and...

Страница 77: ...ways IPG 3901 Reference Panel In the context of a Kaleido Modular X system with KMX 3901 IN IP input output cards the IPG 3901 module must be bounded to the frame controller s URS signal Make sure the...

Страница 78: ...or output card is included in an iControl environment certain information about the card may be made available to the iControl system In the boxes with a white background you can type labels and comme...

Страница 79: ...n it appears in iControl applications This label appears in the service panel s title bar in iControl Solo and in the iControl Navigator views Short label Type the shorter label that iControl uses in...

Страница 80: ...ork Remote system administration Opens the Joining Locators window which lists remote lookup services to which this Kaleido Modular X card is registered Click Add to force the iControl service for thi...

Страница 81: ...ocessing delay is two fields if the video inputs are genlocked and two or three fields if the video inputs are not genlocked In rotation mode the processing delay may increase by one field Signal inpu...

Страница 82: ...loss 15 dB up to 1 5 GHz Alignment jitter 100 kHz 0 2 UI Timing jitter 10 Hz 1 UI Cable length 100 m 328 ft Belden 1694A 45 m 148 ft Belden 1855A 3G SDI inputs Signal SMPTE ST 424 2 97 2 97 1 001 Gbp...

Страница 83: ...5 ft Belden 8281 or Belden 1694A Connector Coaxial via DIN 1 0 2 3 75 ABT audio inputs Signal SMPTE ST 259 C 270 Mbps SMPTE ST 305 Format SDTI Return loss 15 dB up to 270 MHz Alignment jitter 100 kHz...

Страница 84: ...oring a time code source from a timer VTR etc Electrical Reference Input Supported formats SMPTE ST 170 SMPTE ST 318 ITU 624 4 black burst SMPTE ST 274 SMPTE ST 296 tri level sync Connector DIN 1 0 2...

Страница 85: ...umidity 65 RH non condensing Weight KMX 3901 IN 8 D 207 g KMX 3901 IN 8 D 3TRP 97 g KMX 3901 IN 8 D 3 DRP 55 g KMX 3901 IN 16 D 351 g KMX 3901 IN 16 D 3QRP 141 g KMX 3901 IN 16 D 3 DRP 67 g KMX 3901 I...

Страница 86: ...97 On the monitor wall and in XAdmin s Status and Options page 2160p30 is reported as 2160p29 97 SMPTE ST 425 5 12G over 4 3G links Square division quad split 2160p59 94 2160p50 2160p30 2160p29 97 21...

Страница 87: ...Weight KMX 3901 IN 16 Q 381 g KMX 3901 IN 16 Q 3PRP 161 g KMX 3901 IN 16 Q 3 DRP 72 g Ethernet port Physical 2 SFP sockets for copper short reach and long reach fiber Standard IEEE 802 3 2008 10 Gb E...

Страница 88: ...B up to 1 5 GHz Alignment jitter 100 kHz 0 2 UI Timing jitter 10 Hz 1 UI Cable length 100 m 328 ft Belden 1694A 45 m 148 ft Belden 1855A 3G SDI inputs Signal SMPTE ST 424 2 97 2 97 1 001 Gbps Formats...

Страница 89: ...T 424 2 97 2 97 1 001 Gbps Formats Proprietary Audio SMPTE ST 299 Return loss 15 dB up to 1 5 GHz 10 dB up to 3 GHz Alignment jitter 100 kHz 0 3 UI Timing jitter 10 Hz 2 UI Cable length between two in...

Страница 90: ...Max storage humidity 90 RH non condensing Max functional humidity 65 RH non condensing Weight KMX 3901 IN 8 D 207 g IPG 3901 207 g KMX 3901 IN IP D 3 TRP 96 g HDMI outputs Signal HDMI V1 3 Format 1024...

Страница 91: ...o 1 5 GHz Alignment jitter 100 kHz 0 2 UI Timing jitter 10 Hz 2 5 UI Cable length 100 m 328 ft Belden 1694A 45 m 148 ft Belden 1855A Connectors DIN 1 0 2 3 Quantization 8 bits 3G SDI monitoring output...

Страница 92: ...page 25 With the single panel audio monitoring is available at the SDI and HDMI outputs only Analog audio outputs Signal Unbalanced analog stereo Impedance 10 k Level 2 V p p Connector WECO FlexBridge...

Страница 93: ...nel USB Standard USB version 2 0 Peripherals supported Mouse keyboard memory stick Connector USB type A Power consumption KMX 3901 OUT S KMX 3901 OUT D 25 W max Full spec temperature range 0 40 C 32 1...

Страница 94: ...25 Volts max Connector DB 44 GPI bidirectional up to 8 Description Contact closure to GND Signal Open collector 5 to 12 VDC Connector DB 44 Input mode Pull up voltage 2 3 Volts Source current 2 mA wh...

Страница 95: ...95 Kaleido Modular X Hardware Description Installation Manual...

Страница 96: ...n a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from t...