29
[PRODUCT NAME]
[DOCUMENT TYPE]
Power Supply Status LEDs
Power Status LED
There are two power supply inlets in the system (for redundancy). The system can operate with
only one power supply connected. In case the power supply is an FRU, a second power supply
unit can be added to support hot-swap ability. Each power supply unit has a single 2 color LED
on the right side of the unit, that indicates the status of the unit.
GVF-1032-100G Rear Side Panel
The primary power supply (PS) unit is located on the left side, and the secondary unit is located
on the right side.
Power Supply Unit Status Front LED Assignments for GVF-1032-100G
Note:
The table on the previous page - Fan Status Rear LED Assignments
(One LED per Fan) - does not apply to the GVF-516-100G.
IMPORTANT: Risk of Electric Shock! With the fan module removed,
power pins are accessible within the module cavity. Do not insert
tools or body parts into the fan module cavity.
Note:
The following information does not apply to the GVF-516-100G. In
these systems, the power supply units are non-replaceable, and there is a
designated LED for each unit in the system's front panel. (Front panel figures
are located in the Introduction.)
LED Behavior
Description
Action Required
Solid Green
All plugged (one or two) power supplies are
running normally.
N/A
Solid Red
PSU is faulty or disconnected.
Make sure the AC cable is plugged
in and active. If the problem
resumes, the FRUs might be faulty,
and should then be replaced.
Off
N/A
N/A