30
Interfaces
Data Interfaces
Power Supply Unit Status Front LED Assignments for GVF-516-100G
The power supply status LEDs on the rear side of the system (in GVF-1032-100G only) are
located on the PSUs themselves. Each PSU has one LED of its own.
Power Supply Unit Status Rear LED Assignments
Unit Identification LED
The UID LED is a debug feature, that the user can use to find a particular system within a cluster
by turning on the UID blue LED.
To activate the UID LED on a switch system, run:
To verify the LED status, run:
To deactivate the UID LED on a switch system, run:
LED Behavior
Description
Action Required
Solid Green
Power supply is running normally.
N/A
Solid Red
PSU is faulty or disconnected.
Make sure the AC cable is plugged
in and active. If the problem
resumes, the PSU might be faulty.
Off
PSU not present
N/A
LED Behavior
Description
Action Required
Solid Green
Power supply is running normally.
N/A
Flashing Green 1Hz AC present / Only 12VSB on (PSU off ) or PSU in
Smart-on state
Call your Grass Valley
representative for assistance.
Amber
AC cord unplugged or AC power lost while the
second power supply still has AC input power.
Plug in the AC cord of the faulty
PSU.
Flashing Amber
Power supply warning events where the power
supply continues to operate; high temp, high
power, high current, slow fan.
Call your Grass Valley
representative for assistance.
Off
No AC power to all power supplies.
Call your Grass Valley
representative for assistance.
Note:
The table above (Power Supply Unit Status Rear LED Assignments)
does not apply to the GVF-516-100G
switch (config) # led MGMT uid on
switch (config) # show leds
Module LED Status
--------------------------------------------------------------------------
MGMT UID Blues
switch (config) # led MGMT uid on
Содержание grass valley GV FABRIC
Страница 6: ...vi Notices ...
Страница 20: ...14 Installation 19 System Mounting Options ...
Страница 40: ...34 Software Management Upgrading Software ...