![Belden FX Fusion Splicer Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/belden/fx-fusion-splicer/fx-fusion-splicer_user-manual_2725546059.webp)
PX106545-EN, Rev.A
57
Error Messages
7.1
Too dirty fiber
Error message generated when the fiber prepared for splicing contains foreign
substances that exceed a normal level.
Solution: Repeat splice after cleaning the fiber.
7.2
Replace fiber
Error message generated when the fiber is not located properly or there is a foreign
substance on the object lens or reflector.
Solution: Press
and reposition fiber again. Clean the object lens and reflector.
Содержание FX Fusion Splicer
Страница 12: ...PX106545 EN Rev A 10 3 2 Component name Sleeve heater Wind cover Monitor Battery...
Страница 13: ...PX106545 EN Rev A 11 Heater Heater cover Instructions for Use DC in charge in USB...
Страница 27: ...PX106545 EN Rev A 25 Deleting splice mode i Select a mode to be deleted ii Delete it by pressing...
Страница 29: ...PX106545 EN Rev A 27 Deleting heater mode i Select a mode to be deleted ii Delete it by pressing...
Страница 40: ...PX106545 EN Rev A 38 6 3 2 Deletion of splice result Data and images can be deleted in a single step...