PX106545-EN, Rev.A
33
6.2
HEATER
To display heater mode, press
and then select “HEATER”
from the menu using
. The selecting screen is equipped with various heater modes to facilitate easy
selection. Heater mode can be expanded and saved for up to 100 modes. Heater mode
Nos. 1~12 cannot be deleted or replaced.
[Outline of heater mode]
Set value
Description
1.
FX Fusion LC
Micro sleeve for LC type
2.
FX Fusion SC
Micro sleeve for SC type
3.
60mm Type1
Standard 60mm micro sleeve
4.
40mm Type1
Standard 40mm micro sleeve
5.
60mm IS60
60mm micro sleeve
6.
45mm IS45
45mm micro sleeve
7.
45mm Type1
45 mm sleeve
8.
34mm Type1
34 mm sleeve
9.
25mm Type1
25 mm sleeve
10.
20mm Type1
20 mm sleeve
11.
S09 Type1
28mm sleeve for SOC(ST-0.9mm)
12.
S20 Type1
45mm sleeve for 2.0mm cable
Choose the proper mode for each sleeve tube type and SOC.
For the SOC, operators must use Belden standard products. For other sleeves, see
manufacturer specifications and adjust manually.
Heater modes specify temperature, time and heating location on the heater plate.
Содержание FX Fusion Splicer
Страница 12: ...PX106545 EN Rev A 10 3 2 Component name Sleeve heater Wind cover Monitor Battery...
Страница 13: ...PX106545 EN Rev A 11 Heater Heater cover Instructions for Use DC in charge in USB...
Страница 27: ...PX106545 EN Rev A 25 Deleting splice mode i Select a mode to be deleted ii Delete it by pressing...
Страница 29: ...PX106545 EN Rev A 27 Deleting heater mode i Select a mode to be deleted ii Delete it by pressing...
Страница 40: ...PX106545 EN Rev A 38 6 3 2 Deletion of splice result Data and images can be deleted in a single step...