DURAFLO™ 18 GPM PUMPING STATIONS
28
Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
1MANUL375
Maintenance
Pumping Station Float Valve Seal Replacement Kit (#105884)
Removing the Existing Stem Assembly
7) Using an adjustable wrench, loosen and remove the Bonnet.
8) Slide the Stem Assembly out from the Valve Body.
Disassemble the Stem Assembly Components
1) Loosen and remove the Stem as shown by the dotted-arrow. Doing so will free the Cup Seal
and Top Follower. Discard the old Cup Seal but keep the Top Follower.
Loosen the Bonnet
from here
Bonnet
Stem Assembly
Body
Top Follower
Cup Seal
Stem