DURAFLO™ 18 GPM PUMPING STATIONS
1MANUL375
Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470* Ph (248) 349-7010 * Fax (248) 380-9681
9
Specifications
Requirements
Physical
Pump Type
Wanner™ H-25 Hydra-Cell Positive Displacement
Diaphgram
Motor Type
10 HP or 15 HP, 1765 RPM, 3-Phase 208/230/460/575 V
Unloader Type
21 GPM, 4060 psi Discharge Pressure, 1/2” NPT-F ports
Tank Capacity
54 Gal Capacity Max, 31 Gal Max Water Available
Maximum Flow
18 GPM
Maximum Pressure
600 psi for 10 hp motor, 1100 psi for 15 hp motor
Inlet Size
1” NPT, 100 psi Max Water Inlet Pressure
Outlet Size
18 GPM, 1” MJIC
Weight
With 10 hp - 545 Lb (Dry) or
With 15 hp - 685 Lb (Dry)
DISCONNECT AND LOCKOUT ELECTRICAL POWER AND DISSIPATE ANY OTHER
POTENTIALLY HAZARDOUS ENERGY SOURCES ACCORDING TO 29 CFR 1910.147
AND THE EXAMPLE PROVIDED IN 1910.147 APPENDIX ‘A’ BEFORE SERVICING ANY
EQUIPMENT!
Always wear safety glasses when performing maintenance on any equipment
It is recommended that a licensed electrician is contracted to perform all electrical
installations.
A compressed Air System should be set correctly to support 90 PSI necessary to operate
equipment, but should never be set to deliver more than 120 PSI air pressure to the Belanger®
specified equipment.