Safety instructions
BEKOMAT® 33U / 33U CO
5
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos: 12 / Beko Technische Dok um ent at ion/ Sich er heit / M aßnahm en Net zspann ung BM 31U/ 32U/ 33 U @ 7\ m od_13904671 97804_2 901. docx @ 38043 @ @ 1
Measures:
•
During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
•
When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
•
The removed control unit has no IP degree of protection.
•
All types of electrical works must be carried out by authorised and qualified personnel only.
Pos: 13 / Beko Technische Dok um ent at ion/ Sich er heit / Sicher he it shin weis e, weit er e BM ( nicht Ex, nicht I F) @ 0\m od_1183616103 770_29 01. docx @ 4011 @ @ 1
Further safety instructions:
•
For installation and operation, the national regulations and safety codes in force must also be adhered
to.
•
Do not use the BEKOMAT
®
33U / 33U CO in hazardous areas.
•
Regarding the inlet screw joints, excessive tightening forces must be avoided. This applies in particular
to conical screw joints.
•
The BEKOMAT
®
33U / 33U CO will only function when voltage is applied.
•
Do not use the test button for permanent drainage.
•
Use genuine spare parts only. This is imperative to ensure perfect functioning.
Pos: 14 / Beko Technische Dok um ent at ion/ Sich er heit / Zusat z Sicher he it shin weise BM 3 3/ BM 33U @ 0\ m od_1231926 887620_ 2901. docx @ 12830 @ @ 1
Additional advice:
•
During installation, use the spanner flat at the feed pipe (wrench size SW28 + 34) as a back rest.
•
The service unit must not be dismantled.
Pos: 15 / Beko Technische Dok um ent at ion/ Sich er heit / Vor sicht Fehlf unkt i on @ 0\ m od_121437809 6290_29 01. docx @ 9360 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
BEKOMAT .
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos: 16 / Beko Technische Dok um ent at ion/ Sich er heit / M aßnahm en Feh lf unkt ionen BM @ 0\ m od_12143784 34025_2 901. docx @ 9379 @ @ 1
r
Measures:
•
Condensate drainage which is reliable in performance directly optimises the compressed-air quality.
•
To prevent damage and breakdowns, it is imperative to observe the following:
•
Exact compliance with the specifications of use and with the performance parameters of the
BEKOMAT, in connection with the case of application (see "Proper use" section).
•
Exact compliance with the installation- and operation instructions in this manual.
•
Regular maintenance and control of the BEKOMAT in accordance with the instructions in this oper-
ating manual.
Pos: 17 / - -- - Seit enum br uch - -- - @0\ m od_1157028099015_ 0. docx @ 2903 @ @ 1