Control and maintenance
20
BEKOMAT® 33U / 33U CO
Pos: 60 / Beko Technische Dok um ent at ion/ Über schr if t en/ 1/ Kont r olle und War t ung @ 0\ m od_118363788 5371_2 901. docx @ 5439 @ 1 @ 1
12 Control and maintenance
Pos: 61 / Beko Technische Dok um ent at ion/ Sich er heit / G ef ahr Dr uckluf t @ 0\m od_11841481438 54_2901. docx @ 5778 @ @ 1
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping com-
pressed air or through bursting plant components or plant components which are not
secured.
Pos: 62 / Beko Technische Dok um ent at ion/ Sich er heit / M aßnahm en Dr uckl uf t BM @ 0\m od_11841482842 91_290 1. docx @ 5814 @ @ 1
Measures:
•
Do not exceed the maximum operating pressure (see type plate).
•
Only carry out service measures when the system is pressureless.
•
Use pressure-resistant installation material only.
•
The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant
pipe.
•
Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Pos: 63 / Beko Technische Dok um ent at ion/ Sich er heit / G ef ahr Net zspannung 1 s/ w @ 0\ m od_1184148186948 _2901. docx @ 5796 @ @ 1
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos: 64 / Beko Technische Dok um ent at ion/ Sich er heit / M aßnahm en Net zspann ung BM 31U/ 32U/ 33 U @ 7\ m od_13904671 97804_2 901. docx @ 38043 @ @ 1
Measures:
•
During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
•
When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
•
The removed control unit has no IP degree of protection.
•
All types of electrical works must be carried out by authorised and qualified personnel only.
Pos: 65 / Beko Technische Dok um ent at ion/ Sich er heit / Vor sicht Fehlf unkt i on @ 0\ m od_121437809 6290_29 01. docx @ 9360 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
BEKOMAT .
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos: 66 / Beko Technische Dok um ent at ion/ Sich er heit / M aßnahm en Feh lf unkt ionen BM @ 0\ m od_12143784 34025_2 901. docx @ 9379 @ @ 1
r
Measures:
•
Condensate drainage which is reliable in performance directly optimises the compressed-air quality.
•
To prevent damage and breakdowns, it is imperative to observe the following:
•
Exact compliance with the specifications of use and with the performance parameters of the
BEKOMAT, in connection with the case of application (see "Proper use" section).
•
Exact compliance with the installation- and operation instructions in this manual.
•
Regular maintenance and control of the BEKOMAT in accordance with the instructions in this oper-
ating manual.