1 692 846 001
2017-04-27
|
Beissbarth GmbH
40 | VLH 4440 | Maintenance
en
8. Maintenance
!
Work on electrical equipment is only to be
performed by persons with sufficient knowledge and
experience of electrical systems.
8.1
Important notes on maintenance
!
Before starting maintenance work under raised
lifting platform components, these are to be secured
to prevent unintentional movement.
!
In the event of breakage of a loadbearing
component, the loadbearing structures and drive
system including the safety devices are to be
examined to prevent falling or lowering of the
loadbearing element. Damaged parts are to be
replaced.
i
The replacement of suspension cables is to be
recorded in the test log book.
8.2
Cleaning
!
The lifting platform safety devices are not to be
replaced or bypassed during cleaning.
!
Always raise the lifting platform when cleaning the
floor area with detergent.
The lifting platform is only to be cleaned using water
containing a small quantity of neutral or slightly alkaline
detergent. The water temperature must not exceed
25 °C.
The components can be wiped with soft cloths or
sponges. Rinse components with clean water after
cleaning.
!
Never use cleaning agents which corrode paintwork,
coatings or sealing materials:
R
No solvents (esters, ketones, alcohols, halogenated
hydrocarbons)
R
No abrasive cleaning agents (scouring powder)
R
No acidic or highly alkaline cleaning agents
!
Never clean the lifting platform with high-pressure or
steam cleaners.
i
A
preservative agent
(e.g. commercially available
transparent cavity sealant) provides extra protection
for the coating. This should be applied in all areas
with exposed edges or where moisture may ingress.
This does not apply to the top edge of the runway.