Beijing Starfire Control Technology Co.,Ltd.
北京斯达峰控制技术有限公司
Model SF-2012AH-QG
Cutting Machine
(
C002
)
6
Flame machining case:
rise the cutting torch(M72), open the cutting oxygen(M12) and lower the
cutting torch(M73).
Plasma machining case:
execute
M
07 command.
Note:
This is a very important feature. It will be used repeatedly in pause, return and extend piercing
operations. When preheat is done, pressing [PIERCE] key will start up piercing operation
directly.
[SWOFF]: To shut off all the heavy-current output.
[
S
↑]: Push it down to rise the cutting torch and release to stop the torch.
[
S
↓]: Push it down to lower the cutting torch and release to stop the torch.
;
3.1.8[1] BLOWUP
The pattern will be magnified one times by one keystroke and it can be magnified to eight times
maximum by
three keystrokes.
3.1.9 [2] RESTIT
To restore to normal pattern size.
3.1.10 [X] TEST
If [X] key is pressed, the system will run the program at top speed without executing
M
command. This
feature is often used to position quickly or check the working size of steel plate. This operation can be paused at any
moment or cancelled by pressing [X] key one more times.
3.1.11 [Y] AU-SPD
Since the manual speed and automatic speed is separate in the system, this key is used to switched between
automatic mode and manual mode to adjust the speed multiplying factor.
3.2. Function selection inAUTO mode
It is allowed to invoke a machining program by means of
EDIT
feature. If a program has been invoked(as long as it is the same
program name), it can be run directly. If the program is invoked from an USB disk, especially a large program, it can be run directly with
USB disk connected instead of saving it into the system.
3.2. 1[F1] SECTION
To assign system to start up machining operation from any section or piercing point.
It is often used when machining needs to start from a certain section or only a part needs being processed.
Refer to
SECTION
feature for details.
3.2.2[F2] MAN
To switch the system to manual mode.
3.2.3[F3] RESBREK
After this function is selected, pressing [
START
] key to fulfill breakpoint restoration. Refer to
RESBREK
feature for details.